Trade name / Models : atlantic / alfea
geolia 5
geolia 7
geolia 10
Reference
522452
522453
522454
Space heating application
35°C
55°C
35°C
55°C
35°C
55°C
Water/water information
Declared capacity for heating for part load at indoor temperature 20°C and outdoor temperature Tj
Tj = -7°C
Pdh
kW
7 4
6 8
9 4
8 5
13 4
12 4
Tj = +2°C
Pdh
kW
7 6
6 9
9 5
8 8
13 5
12 8
Tj = +7°C
Pdh
kW
7 7
7 1
9 6
9 0
13 6
13 0
Tj = +12°C
Pdh
kW
7 7
7 2
9 7
9 2
13 7
13 3
Tj = bivalent temperature
Pdh
kW
7 4
6 8
9 4
8 5
13 4
12 4
Tj = operation limit temperature
Pdh
kW
7 3
6 7
9 4
8 3
13 3
11 8
Degradation coefficient
Cdh
(3)
-
0 99
0 99
0 99
0 99
0 99
0 99
Bivalent temperature
T
biv
°C
-7
-7
-7
-7
-7
-7
Declared coefficient of performance or primary energy ratio for part load at indoor temperature 20°C and outdoor temperature Tj
Tj = -7°C
COP
d
-
5 16
3 30
4 80
3 30
5 71
3 74
Tj = +2°C
COP
d
-
5 53
4 00
5 10
3 90
6 03
4 67
Tj = +7°C
COP
d
-
5 81
4 40
5 30
4 30
6 48
5 29
Tj = +12°C
COP
d
-
6 10
4 90
5 60
4 80
6 68
5 91
Tj = bivalent temperature
COP
d
-
5 16
3 30
4 80
3 30
5 71
3 74
Tj = operation limit temperature
COP
d
-
5 00
3 10
4 70
3 00
5 27
3 27
Heating water operating limit temperature
WTOL
°C
55
Supplementary heater
Rated heat output
(2)
P
sup
kW
1 1
1 0
1 2
1 2
1 8
2 3
Type of energy input
-
-
Electrical
Other items
Capacity control
-
-
All or nothing
Rated brine flow rate in outdoor heat exchanger
-
m
3
/h
1 68
1 30
2 12
1 59
3 10
2 34
Brine/water information
Declared capacity for heating for part load at indoor temperature 20°C and outdoor temperature Tj
Tj = -7°C
Pdh
kW
5 7
NA
7 0
NA
10 2
NA
Tj = +2°C
Pdh
kW
5 8
NA
7 2
NA
10 3
NA
Tj = +7°C
Pdh
kW
5 7
NA
7 2
NA
10 4
NA
Tj = +12°C
Pdh
kW
5 7
NA
7 3
NA
10 6
NA
Tj = bivalent temperature
Pdh
kW
5 7
NA
7 0
NA
10 2
NA
Tj = operation limit temperature
Pdh
kW
5 6
NA
7 0
NA
10 1
NA
Degradation coefficient
Cdh
(3)
-
0 99
NA
0 99
NA
0 99
NA
Bivalent temperature
T
biv
°C
-7
NA
-7
NA
-7
NA
Declared coefficient of performance or primary energy ratio for part load at indoor temperature 20°C and outdoor temperature Tj
Tj = -7°C
COP
d
-
3 90
NA
3 87
NA
4 08
NA
Tj = +2°C
COP
d
-
4 10
NA
4 05
NA
4 33
NA
Tj = +7°C
COP
d
-
4 30
NA
4 22
NA
4 56
NA
Tj = +12°C
COP
d
-
4 40
NA
4 39
NA
4 80
NA
Tj = bivalent temperature
COP
d
-
3 90
NA
3 87
NA
4 08
NA
Tj = operation limit temperature
COP
d
-
3 90
NA
3 78
NA
3 98
NA
Heating water operating limit temperature
WTOL
°C
50
NA
50
NA
50
NA
Supplementary heater
Rated heat output
(2)
P
sup
kW
0 8
NA
0 9
NA
1 7
NA
Type of energy input
-
-
Electrical
Other items
Capacity control
-
-
All or nothing
Rated brine flow rate in outdoor heat exchanger
-
m
3
/h
1 24
NA
1 53
NA
2 23
NA
Operation manual "1639 - EN"
- 25 -
Ground source heat pump atlantic geolia