3 4 3 Selecting and setting the DHW operating mode (option)
• Change the DHW operating mode
To change from "Active" mode to "Off" mode, press several times the
DHW mode
key
Marche
Arrêt
DHW On :
DHW according to the time program
Manual start button (forced mode) :
Hold on the DHW key for 3 seconds Switch from "reduced"
to "comfort" for one DHW load)
Marche
Arrêt
DHW Off :
DHW stopped with frost protection active
• Set point settings for DHW temperature
(DHW kit / option)
Press
OK
to go to "End user" level
Line No. Selection
Settings
-
- Heating circuit 2
-
Domestic Hot Water
- Fault
-
OK
1610
OK
Comfort setpoint
(set from "Reduced setpoint" to 65°C)
Eg :
55
°
C
OK
1612
OK
Reduced setpoint
(set from 8°C to "Comfort setpoint")
Eg :
40
°
C
OK
Return to the previous display, press several times
ESC
• Change DHW heating periods
(menu "Time program 4 / DHW")
The time DHW heating program is set by default for the entire week (Mon-Sun : from Monday to Sunday)
and 0:00 a m to 5:00 a m (1
st
DHW heating phase) and 14:30 a m to 17:00 a m (2
e
DHW heating phase)
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
ON
DHW heating
DHW heating
1
st
phase
2
e
phase
OFF
OFF
ON
For your convenience, you can set up to 3 DHW heating phases and different periods (week, day, ...).