3 4 2 Selecting and setting the heating operating mode
• Selecting the heating operating mode
To select the heating operating mode, press several time on
mode
"Auto" :
Auto
Automatic mode controls room temperature according to
the time program
"Constant" :
Constant mode maintains constant room temperature at
selected operating
COMFORT Mode
REDUCED Mode
"Stand-by" :
Stop with frost protection
(Provided that the heat pump's electrical power supply is
not interrupted)
• Set point settings for heating temperature
(Comfort, Reduced, Stand-by)
Press
OK
to go to "End user" level
Line No. Selection
Settings
-
- Holidays heating circuit 2
-
Heating adjustment circuit 1
- Heating adjustment circuit 2
-
OK
710
OK
Comfort setpoint
(set from "Reduced setpoint" to 28°C)
Eg :
20
°
C
OK
712
OK
Reduced setpoint
(set from "Frost protection setpoint" to "Comfort setpoint")
Eg :
17.5
°
C
OK
714
OK
Frost protection setpoint
(set from 4°C to "Reduced setpoint")
Eg :
7
°
C
OK
Return to the previous display, press several times
ESC
Use the same procedure to program the second heating circuit (heating circuit 2 / option kit 2 circuits) Lines 1010, 1012
and 1014
• Change heating periods
(menu "Heating time program x")
The time heating program is set by default for the entire week (Mon-Sun: from Monday to Sunday)
and 6:00 a m to 10:00 p m in comfort mode (from 10:00 p m to 6:00 a m in reduced mode)
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
ON
Reduced T°
Reduced T°
Comfort T°
1
st
phase
OFF
For your convenience, you can set up to 3 heating phases and different periods (week, day, ...).
Operation manual "1639 - EN"
Ground source heat pump atlantic geolia
- 12 -