Atlantic 412236 Fitting Instructions Manual Download Page 3

3

1. WARNINGS

READ INSTRUCTIONS BELOW CAREFULLY BEFORE INSTALLATION:

If the advice and warnings in these instructions are ignored, the manufacturer cannot assume liability for any injury or damage suffered 
by people or property.
The instructions describe how to install, use and maintain the appliance correctly. Respecting these instructions ensures effective and 
sustainable use of the appliance. 
Do not use this appliance for any purpose other than that for which it is intended.
After unpacking, check it is in good condition. If there are any problems, contact your dealer for help.
Use of any electrical appliance implies respect for the following basic rules:
- do not touch the appliance with moist or wet parts of the body (hands, feet, etc.).
- this appliance is not designed for use by people (including children) of reduced physical, sensory or mental capacity, or those inexperienced 
or ignorant, unless they have received prior instruction or supervision in the use of the appliance from someone responsible for their safety. 
Children must be supervised to ensure they do not play with the appliance.
- The appliance is designed to be installed inside a building. Do not connect the appliance to the main electricity supply unless it complies 
with the specifications shown on the information plate. 
- before working on the appliance, turn off the electricity supply and make sure it cannot be restored accidentally.
- Provide a 2A circuit-breaker for protection upstream.
This equipment must be installed by suitably qualified persons.
The installation must comply with NF C 15-100 and with professional standards. Each product or component of the installation must also 
comply with the relevant standards.

2. DESCRIPTION

2.1 General points

Dual flow control unit for private house, from T2 to T7, with a maximum of 4 washrooms. Horizontal installation in roofspace, ideal for 
renovation and replacement of existing products. 
Primocosy HR / HR SRI: High-performance heat exchanger.
BY-PASS function for the exchange to bring cool air in during summer nights.
Individual room airflow controls with regulators in the connection points. Automatic, built-in de-icing system. Hi-flow kitchen intake with 
remote controls (SRI model) or switch.

2.2 Construction

Insulated casing in PPE and sheet steel cover with foam insulation. G4 filters on intake and extraction, fitted on metal frames.
Primocosy HR: High-performance, contraflow exchange, low-energy EC 2-speed motors.

2.3 Composition

• 4 washroom connection points, Ø80 regulated at 15 or 30 m3/h.
• 2 Ø80 plugs.
• 1 kitchen connection point Ø125 regulated.
• 1 used air discharge connection point Ø125.
• 1 fresh air intake connection Ø125.
• 1 forced intake connection point Ø125.
• 8 clamping sleeves.
• 1 siphon fitted to the product for condensate collection.
• 1 switch for hi-flow kitchen connection, BY-PASS or 
   1 radio remote control for SRI versions.
• 1 filter clogging indicator panel.

4 washroom connection 

points, Ø80 regulated at 

15 or 30 m3/h

1 used air discharge connection point Ø125

1 forced intake connection 
point Ø125

1 kitchen connection point Ø125 
regulated

1 connection point 

for fresh air Ø125

2 Ø80 plugs

SRI version

1 radio remote control

1 clamping collar for 
connecting condensate 
discharge

1 switch for 

kitchen hi-flow 

Standard version

Composition for all models

MODE D’EMPLOI
1/ 

 

Appuyer pour enclencher la pastille 

 

2/ 

 

Lorsque le témoin rouge atteint 

(réf. : 412190)

INDI

C

ATEUR

 DE

 CHANGEMENT 

 

DE FI

LTRES VMC

www.boutique-atlantic.fr

Avec cette carte, suivez l’usure 

quand les changer.

Filtres disponibles sur la boutique Atlantic :

1 filter clogging 

indicator panel

Summary of Contents for 412236

Page 1: ...FITTING INSTRUCTIONS PRIMOCOSY HR BP HR SRI BP 412236 412237 Family 4 N 4126 Issue Date 02 2017 ...

Page 2: ...3 3 Connection of air flow associated terminals 6 4 ELECTRIC CABLING 7 5 EXTRACTION FLOW RATE ADJUSTMENT 8 5 1 Extraction flow rate adjustment 8 5 2 Washroom flow rate settings 8 6 BY PASS PRINCIPLE 9 7 ACCESSORIES NOT SUPPLIED 9 8 ANNUAL MAINTENANCE 10 8 1 Filter clogging indicator 10 8 2 Changing filters 10 8 3 Maintenance of exchanger and motorised fans 11 9 WARRANTY 12 10 PROTECTING THE ENVIRO...

Page 3: ...ards 2 DESCRIPTION 2 1 General points Dual flow control unit for private house from T2 to T7 with a maximum of 4 washrooms Horizontal installation in roofspace ideal for renovation and replacement of existing products Primocosy HR HR SRI High performance heat exchanger BY PASS function for the exchange to bring cool air in during summer nights Individual room airflow controls with regulators in th...

Page 4: ...igh speed versions For SRI 23 hr low speed versions and 1hr high speed versions 2 5 Dimensions Current Power consumption Weighted power PV GV PV GV PRIMOCOSY HR 0 4A 0 6A 40W 122W 47 1 W th C PRIMOCOSY HR SRI 0 4A 0 6A 40W 122W 43 7 W th C 4 9 0 700 300 Ø125 Ø125 3 X Ø80 Ø125 Ø80 70 700 70 Ø125 Fixed plate 70 490 70 ...

Page 5: ...ed under the product after installation Check the sealing of the whole assembly and the run off of the condensates WARNING Check the discharge pipe never rises above the level of the condensates connector For easier maintenance leave a 300mm space above and behind the appliance 3 cm or 5 Condensates connection OK NOK Note Condensates connection has a built in siphon There is no need to install ano...

Page 6: ...hrooms Ø80 Kitchen connection with regulator X 1 X 3 Fresh air inlet Used air outlet Fresh air blowing Washroom extraction Kitchen extraction To prevent unwanted load losses it is vital to avoid unnecessary elbow joints to extend straight sections without pulling not to crush the conduits to limit the length of the conduits to plug unwanted outlets with the plugs supplied Example of system with di...

Page 7: ...er clip into the hole to do a reset See the SRI remote control manual for the parameters PRIMOCOSY HR SRI BP BROWN PHASE EARTH NEUTRAL CASING CABLE FACTORY WIRING INSTALLER WIRING BLUE OR GREY 230V POWER SUPPLY 4 ELECTRIC CABLING RESET access This equipment must be installed by suitably qualified persons The installation must comply with NF C 15 100 and with professional standards Each product or ...

Page 8: ... cubicle Single Multiple 2 3 4 5 and more 90 105 120 135 15 30 30 30 15 15 30 30 15 15 30 30 15 15 15 15 Check the terphane flap is in the correct position in the WC connection Identification of connection SDB 30 m h Identification of connection WC 15 m h Correct position Section view Wrong position Section view If the flap is in the wrong position put it in the correct one Section view Replace th...

Page 9: ...ne fois le réseau installé il est né cessaire de régler les bouches d insuffl ation ai équiréparti dans toutes les pièces Pour cela ouvrir toutes les bouches du réseau C la plus éloignée de la centrale véri fier qu il y a un débit minimum Ensuite passer quelques tours puis répéter l opération sur toutes les bouches d insufflat ion en le au fur et à mesure que l on se rapproche de la centrale Warm ...

Page 10: ...d les changer Filtres disponibles sur la boutique Atlantic MODE D EMPLOI 1 Appuyer pour enclencher la pastille 2 Lorsque le témoin rouge atteint réf 412190 INDICATEUR DE CHANGEMENT DE FILTRES VMC www boutique atlantic fr Avec cette carte suivez l usure quand les changer Filtres disponibles sur la boutique Atlantic When the indicator is full change the filters A new indicator is supplied with repla...

Page 11: ...the right way round taking care the closure hooks are properly in place Screw up the 4 crosshead screws Pull out the motorised fan units to dust them with a dry brush Motorised fan unit Disconnect the terminal strip before removing the BY PASS exchanger assembly Grasp at the sides and pull out upwards Carefully clean the exchanger using a domestic vacuum cleaner DO NOT USE LIQUID OF ANY KIND WHETH...

Page 12: ...nce is guaranteed against all manufacturing faults for two years from the date of purchase For this ATLANTIC Climatisation et Ventilation offers exchange or supply of parts found to be defective after inspection by its after sales service In no case may the warranty cover additional costs such as labour transport or compensation of any kind The warranty does not cover damage caused by installation...

Reviews: