6.6.2
USER PORT CONFIGURATION
6.6.2.1
V35 USER PORT
Data Rate: The data rate can only be set by the ‘master’ unit and is set in increments of 64kbps.
The data rate is set by entering the desired value of N from 1 (64kbps) to 36 (2304kbps). The
default value of N is 32.
Timing Options: The timing options can only be set by the ‘master’ unit.
OM25 Thu 01 Jan 1970
Configuration > User Port
Urgent Alarm:On Non-Urgent Alarm:Off
Subsystem: Master
Port Type: OM25-V35
Rate (nx64): <32> Enable Loops:
Timing Control Lines:
Internal: (*) 106 Clamp On:
External: ( ) 107 Clamp On:
Loop: ( ) 109 Clamp On:
End-to-end Signalling
Press Return to Accept or Escape to Cancel
F1 Help F3 Previous Menu F4 Main Menu F7 Previous Subsystem
F8 Next Subsystem
Configuration
Master/Slave
User Port
Master / slave configuration
Configure User Port
System
Subsystem Names
Monitoring
Reboot
Serial Communications
Front Panel
Allows you to reboot the system
Set date, time and menu timeout
Enter name, description and location of this unit.
Configures monitoring mode
Terminal set-up - baud rate, parity and handshake
Allows configuration of Front Panel controls