27
ATIM_ACW-MR4_UG_EN_V1.5
The data contained in the frame will then include the value of the four inputs as well as a flag indicating which input
has been triggered (note that bits 4 - 7 will always be at "0" in a periodic measurement frame).
EXAMPLE
0xA0 01 12 => Input 1 change from high to low state (0x12 = 0b00010010).
0xA0 01 21 => Input 2 change from high to low state (0x21 = 0b00100001).
0xA0 01 03 => Every input flag is set to 0 (0x03 = 0b00000011). It means this frame is a periodical measurement
frame and has not been sent after an input state change.
Alert measurement frame
NOTE
The ACW-MR4, alerts only apply when a counter is exceeded.
If the Timestamp is activated, 4 bytes with the Timestamp value will be preceded by the header (byte 1).
For each of the channels in alert a header is inserted and is constituted as follows:
Byte1
Byte2
Byte3
Frame header
(0xA0 without timestamp)
(0xE0 with timestamp)
Channel header
(0x01)
Data
Byte3 (Data)
Bit7
Bit6
Bit5
Bit4
Bit3
Bit2
Bit1
Bit0
IN4 state
change Flag
IN3 state
change Flag
IN2 state
change Flag
IN1 state
change Flag
IN4 state
IN3 state
IN2 state
IN1 state
Byte 1 - Header
Bit7
Bit6
Bit5
Bit4
Bit3
Bit2
Bit1
Bit0
New
generation
= 1
Timestamp
Measurement
frame
= 0
Reserve
d
= 0
Alert frame
= 0x0d
Channel Header
Bit7
Bit6
Bit5
Bit4
Bit3
Bit2
Bit1
Bit0
Alert type
Number of the channel
Measurement type