![ATIM ACW/LW8-MR1 User Manual Download Page 16](http://html.mh-extra.com/html/atim/acw-lw8-mr1/acw-lw8-mr1_user-manual_2999325016.webp)
15
ATIM_ACW-MR1_UG_EN_V1.6
Format of Sigfox
–
LoRaWAN frame
The data vary according to the type of frame transmitted and the operating mode (Meter, On/Off, MR1-Elec).
For example:
*Tref = time of issue
TYPE
DESCR.
FRAME FORMAT
octet 0
(dec)
octet 0
(hex)
octet 1
(hex)
octet 2
(hex)
octet 3
(hex)
octet 4
(hex)
octet 5
(hex)
octet 6
(hex)
octet 7
(hex)
octet 8
(hex)
octet 9
(hex)
octet 10
(hex)
octet
11
(hex)
KEEP ALIVE
Keep alive frame
1
01
Supply voltage
IDLE (mV)
Supply voltage
TX (mV)
64
METER
READING
Standard meter
frame
20
14
00
Meter index 1
0x00000000
TRIGGER
Change of state
detection frame
(Dry contacts)
9
09
00
XX
bit7
bit6
bit5
bit4
bit3
bit2
bit1
bit0
0
0
0
0
0
0
0
Logic
Level
IN2+
METER
MULTI-
READING
LoRaWAN
ECO mode meter
frame (meter 1 6
indexes 32 bits)
48
30
Index 5 (
32bits
)
(Tref-50min)
Index 4 (
32bits
)
(Tref-40min)
Index 3 (
32bits
)
(Tref-30min)
Index 2 (
32bits
)
(Tref-20min)
Index 1 (
32bits
)
(Tref-10min)
Index 0
(
32bits
)
(Tref)
Test frame
49
31
Index cpt 1
(
32bits
)
METER
MULTI-
READING
Sigfox
Trame
ECO mode meter
frame
(Meter 1
20 bits and
5 deltas 12 bits
concatenated)
57
39
Réf. Index
(20 bits)
(Tref)
Delta 1 (12bits)
(Tref-10min)
Delta 2 (12bits)
(Tref-20min)
Delta 3 (12bits)
(Tref-30min)
Delta 4 (12bits)
(Tref-40min)
Delta 5 (12bits)
(Tref-50min)
58
3A
Delta 1 (12bits)
(Tref-30min)
Delta 2 (12bits)
(Tref-60min)
Delta 3 (12bits)
(Tref-90min)
Delta 4 (12bits)
(Tref-120min)
Delta 5 (12bits)
(Tref-150min)
59
3B
Delta 1 (12bits)
(Tref-60min)
Delta 2 (12bits)
(Tref-120min)
Delta 3 (12bits)
(Tref-180min)
Delta 4 (12bits)
(Tref-240min)
Delta 5 (12bits)
(Tref-300min)