Models concerned : 

ACW/SF8-THM-I 

ACW/LW8-THM-I 

ACW/SF8-THM-O 

ACW/LW8-THM-O

 

 

Atim Cloud Wireless

®

  

Temperature & Humidity Sensor  

User's guide

 

Summary of Contents for ACW/LW8-THM-I

Page 1: ...Models concerned ACW SF8 THM I ACW LW8 THM I ACW SF8 THM O ACW LW8 THM O Atim Cloud Wireless Temperature Humidity Sensor User s guide ...

Page 2: ...emperature and humidity sensor 5 Housing 6 a Identification 6 b Assembly and disassembly 7 c Installation 8 Operation 9 a Product start up 9 b Periodic frames 9 c Trames de vie 9 Configuration 9 Frame format 10 Sigfox and LoRaWAN 10 Downlink 11 a Frequency of emission of the line frame 11 b Temperature and hygrometry measurement period 11 a Pairing to the LoRaWAN network 11 Example of data visuali...

Page 3: ...ice and does not represent a commitment on the part of ATIM radiocommunications ATIM radiocommunications provides this document as is without warranty of any kind either expressed or implied including but not limited to the implied warranties of merchantability or fitness for a particular purpose ATIM radiocommunications may make improvements and or changes in this manual or in the product s and o...

Page 4: ...ty Article 3 1a of Directive 1999 5 EC NF EN60950 1 Ed 2006 A1 2010 A11 2009 A12 2011 health EN62479 2010 power 20mW or EN62311 2008 power 20mW 2 Electromagnetic compatibility Article 3 1b of Directive 1999 5 EC EN 301489 3 v1 4 1 EN 301489 1 V1 9 2 3 Efficient use of the radio frequency spectrum Article 3 2 of Directive 1999 5 EC ETSI EN300 220 2 v2 4 1 and EN300 220 1 v2 4 1 ...

Page 5: ...is product should not be disposed of with your other household waste Instead it is your responsibility to dispose of your waste by taking it to a designated collection point for the recycling of electrical and electronic equipment Separate collection and recycling of your waste at the time of disposal will help conserve natural resources and ensure environmentally and human health friendly recycli...

Page 6: ...eries 3 6V 7 2Ah Storage mode battery depassivation Radio rate Sigfox 100 bits s LoRaWAN 300 bits s to 10 Kbit s 865 870 MHz Europe zone Frequency 25 mW 14 dBm Power Sigfox LoRaWAN Consumption 25 mA 50 mA Tx mode 5 µA 1 µA Standby mode 17 mA 22 mA b Temperature and humidity sensor Parameter Typical value Temperature accuracy 0 3 C from 0 C to 65 C Humidity accuracy 3 RH from 10 to 90 RH Temperatur...

Page 7: ...e The reading of this code indicates for example the following information for an ACW LW8 TH ATIM ACW LW8 TH C 0 190114 1 3 0 5 11 70B3D59BA0008C0A Interpretation ATIM ACW LW8 TH C 0 190114 1 3 0 5 11 70B3D59BA0008 C0A Manufacturer name Product reference Revision version Date of manufacturing Manufacturing site Hardwar e version Applicati on firmware version Sigfox identifier or DevEUIE LoRaWAN Da...

Page 8: ...r mettre le produit sous tension appuyez sur le bouton poussoir pendant 2 secondes la LED doit clignoter 3 fois pour indiquer le passage en mode exploitation Match the pivots at the top of the case base with their respective locations on the back panel To remove both sides place a screwdriver in one of the two mounting areas at the bottom of the front panel and press inward until the base cover is...

Page 9: ...eight of 1 5m The antenna is integrated in the box The product should be mounted on a vertical support or fixed to a wall WARNING Do not install on a metal pole The product incorporates a digital temperature and humidity sensor The values are read according to the period defined by the network Downlink By default this period is set to a measurement every hour ...

Page 10: ...start it it is necessary to press the push button on the rear panel for 2 seconds see previous page b Periodic frames This reading and transmission period is adjustable by the user with a minimum of 10 minutes NOTE By default this period is set to every hour c Trames de vie Celles ci sont émises une fois par jour ou une fois tous les 4 jours NOTE By default the period for sending life frames is se...

Page 11: ...hex Keep Alive Life frame 1 01 Supply voltage IDLE mV Supply voltage TX mV 64 Test Test pattern 5 05 Counting TH Temperature humidity plot 23 17 Temperature value Humidity value Sensor data is decoded as follows T C 𝑇𝑒𝑚𝑝𝑒𝑟𝑎𝑡𝑢𝑟𝑒 𝑣𝑎𝑙𝑢𝑒 175 72 65536 46 85 H RH 𝐻𝑢𝑚𝑖𝑑𝑖𝑡𝑦 𝑣𝑎𝑙𝑢𝑒 125 65536 6 NOTE The battery voltage of the product is good if Supply voltage is higher than 2 9V ...

Page 12: ...s NOTE DEFAULT VALUE 4 days 01 b Temperature and hygrometry measurement period Parameter code Octet 1 Parameter value Octet 2 0x0C 0xYY 0x0D 0xZZ The measurement period will be every 0xYY hours and 0xZZ minutes The hours must be between 0 and 24 hours Minutes must be between 0 and 59 min EXEMPLE If 0xYY 0x02 and 0xZZ 0x0A the product will make a measurement every 2h10 NOTE DEFAULT VALUE 1h00 01 00...

Page 13: ...12 ATIM_ACW THM_UG_EN_V1 3 Example of data visualization on the ACW platform ...

Page 14: ...erly connected to the modem Check if the modem has been registered to the network Check if network coverage is available Check if the light is illuminated when transmitting Technical support For any information or technical problem you can contact our technical support on this page Technical support ATIM ...