18
Possible problems
Before each fault elimination:
−
Switch off device.
−
Wait for standstill of the device.
−
Pull out mains plug.
Problem
Possible cause
Remedy
Motor won't start
No mains power (power failure)
Check fuse (10 A)
Connection lead defect
Replace lead or have lead checked (electrician)
Never use defect lead
Motor or switch defect
To solve the problem, contact the manufacturer or an
authorised company.
Material is not sucked in
properly
(reduced vacuuming
power)
Machine is clogged or blocked
Eliminate the blocking, call the service if required.
Bag too full
Empty bag
Extension cable too long, or cross-section too small.
Socket too far away from main connection, and
cross-section of connection lead too small.
Extension cable at least 1,5 mm
2
, maximum 25 m
long. Cross- section of at least 2,5 mm
2
in longer
cables.
In case of further faults or inquiries please contact your local dealer.
Technical data
Type
KLS 1600
Model
KLS 1600
Year of construction
see last page
Motor power P
1
1600 W
Motor
AC-motor 230 – 240 V ~ 50 Hz
Speed n
11000 min
-1
Blowing air flow (max. air velocity)
Blow nozzle: 200 km/h
Blow hose: 400 km/h
Suction power (max. air flow)
900 m³/h
Hand arm vibration (as per EN 1033/DIN 45675)
Measuring uncertainty
a
vhw
= < 4.4 m/s²
K = 2.2 m/s²
Bag (volume)
25 l
Protection class
II – protective insulated
Weight
6.8 kg
Sound power level L
WA
(as per 2000/14/EC)
Measuring uncertainty
measured sound power level 105 dB (A)
guaranteed sound power level 108 dB (A)
K = 3 dB (A)
Sound pressure level L
PA
(as per 2000/14/EC)
Measuring uncertainty
94 dB (A)
K = 3 dB (A)
Guarantee
Please observe the enclosed terms of guarantee.
Technical modifications reserved!