Setting code number and definition 

 

Code number 

Description 

Code number 

Description 

2419 

Reset to default 

8016-8017 

Reserved  

2500-2549 

Reserved  

8018-8020 

Video format 

8000-8003 

Primary/secondary receiver 

8401-8499 

Unlock time 

8004-8005 

Enable concierge unit 

8505-8520 

Reserved  

8006-8007 

Panel ON/OFF 

9017-9018 

Reserved  

8008-8009 

Date mode 

9030-9031 

Reserved  

8010-8011 

Unlock mode: Close/Open 

9101-9104 

Door entry panel quantity 

8012-8013 

Time mode: 12hours/24hours 

9200-9216 

Camera quantity 

 

Concierge unit 

 
A receiver can be used as a concierge unit to the system. Follow below steps to enable this 
function. 
 

1. 

Select 

Settings

 from the 

Main Menu. 

 
2. 

Press and hold for 3 seconds the 

Unlock key

 button. 

 
3. 

On the keypad, type  

 
a. 

8004 to enable the concierge function on the monitor. 

b. 

8005 to disable the concierge function on the monitor. 

 

Date and time format 

 
The format of the date or time can be set in two ways. Follow below steps to change the format of 
the date or time. 
 

1. 

Select 

Settings

 from the 

Main Menu. 

 
2. 

Press and hold for three seconds the 

Unlock key

 button. 

 
3. 

On the keypad, type  

 
a. 

8008 to use the date format month/day/year. 

b. 

8009 to use the date format day/month/year. 

c. 

8012 to use the time format of 12hours. 

d. 

8013 to use the time format of 24hours. 

Summary of Contents for A1702

Page 1: ...A1702 2 Wire Video Receiver User manual ...

Page 2: ... adjustments 6 Image adjustments 6 Volume adjustments 6 Door release 6 Call another room or apartment Intercom 6 Do Not Disturb 7 General settings 7 Ring tone setting 7 Ring tone volume 8 Setting screen time 8 Intercom function 8 Restoring the default settings 9 Installer menu 9 Concierge unit 10 Date and time format 10 Unlock mode 11 Unlock time 11 Setting the user code 11 ...

Page 3: ...unlock the door Connection port BUS terminal and monitor addressing Terminal description SW SW Extra doorbell call button connection port Ring GND Extra buzzer connection port POW GND 12 16V extra power connection port DIP switches Total 6 bits can be configured Bit1 Bit5 User code setting switch Bit6 Video impedance matching switch L1 L2 BUS line terminal Mounting A Embed the mounting boxinto the...

Page 4: ...age while the receiver is in communication Answering a call 1 Touch Talk Mon button to answer the call To end the call touch the button again 2 If necessary during the call touch the Setting button to display the audio video settings 3 To unlockthe doorto the visitor touch the door lock key button An indicator thatthe door lock has been released will displayon the screen briefly ...

Page 5: ...door entry panel press the Monitor button to cycle through 3 Touch the Back arrow to return to previous menu Zoom If you want to see more details you can move to the desired positionby touching the magnifying glass button and choose a part on the screen to ZOOMthe image view Note Thisfunction requiresa fisheye cameralens Scale To adjust the Scale of the image use one of the following two modes 1 4...

Page 6: ... the range zero to nine by pressing the or Door release When a visitor pushesthe call button from the entry panel the receiverwillstart ringing To answer the call touch Talk Monbutton Press the unlock button to release the primarydoor If the call comesfroma secondary entrance press unlock2nd button Checkwith your installer if the lock iselectricand if it can connect to the system Call another room...

Page 7: ...tivate the Do Not Disturb function Note The indicator changes to GREEN to indicate that the Do Not Disturb function is ON The indicator is GREY when the function is OFF When the function is turned ON you will not receive any calls General settings Ring tone setting The ring calltone can be set individuallyto distinguish different calling sources There are a total of 12 ring tones to choose from 1 ...

Page 8: ...er 30 secondsof inactivity the screen willturn off This setting can be adjusted as needed by choosing between a range of sixseconds and up to 10 minutes 1 Select Settings from the Main Menu 2 Press the Screen time button 3 Use up and down arrows to scrollthrough the time setting Intercom function The intercom function can be enabled or disabled as required 1 Select Settings from the Main Menu 2 Pr...

Page 9: ...store button on the side menu 4 Press the Check button to confirm alternativelyif you want to Cancel pressthe X button Note The system willsound a beep when the restore to factorysettingshasfinished Installer menu To enter the Installer menu follow below steps 1 Select Settings from the Main Menu 2 Press and hold for three seconds the Unlock key button 3 On the keypad type the installercode accord...

Page 10: ...sed as a concierge unit to the system Follow below stepsto enable this function 1 Select Settings from the Main Menu 2 Press and hold for 3 secondsthe Unlock key button 3 On the keypad type a 8004 to enable the concierge function on the monitor b 8005 to disable the concierge function on the monitor Date and time format The format of the date ortime can be set in two ways Follow below stepsto chan...

Page 11: ... Unlock key button 3 On the keypad type 8401 for one second 8499 for 99 seconds to set the unlocktime Setting the user code On the ATIGO system everyreceiver must have assigned an identification code called User Code DIP Switch addresses The DIP switchesare used to set the user code for each monitorand maximum are 6 Bits Bit 1 Bit 5 are used for addressing Thevalue range is from 0 to 31 a total of...

Page 12: ...er anyimpact 2 Please clean the screen with a soft cotton cloth without using anyorganicorchemical cleaning agent If necessary please use as little as possible water ordilute soap into water to clean the dust 3 Image distortion may occurif the monitor ismounted too close to magnetic fields like TV s microwaves computers etc 4 Please keep away from high temperatures dust oxidation orwater to avoid ...

Reviews: