Manual, Tool Changer, QC‑50
Document #9620‑20‑B‑50 Tool Changer‑04
Pinnacle Park • 1031 Goodworth Drive • Apex, NC 27539 • Tel: 919.772.0115 • Fax: 919.772.8259 •
B-12
2.9 Optional K Series Module Installation
Tools required: 2.5 mm hex key, torque wrench
Supplies required: Clean rag, Loctite 222
1. If the Tool Changer is in service, place the Tool in a secure location.
2.
Uncouple the Master and Tool plates.
3. Turn off and de‑energize all energized circuits; for example, electrical, air, water, etc. If required, fully
disconnect these circuits.
4. Clean the mounting surfaces of the Tool plate, Master plate, and modules.
5. Align the optional module on flat “C” of Master or Tool plate assembly.
6.
If not using fasteners with pre‑applied adhesive, apply Loctite 222 to M3 mounting fasteners. Secure
module with (2) M3 mounting fasteners using a 2.5 mm hex key. Refer to
your specific mounting fasteners. Note: To install the module on the Master, the Master plate might have
Section 2.3—Master Plate Removal.
7. Remove all protective caps, plugs, tape, etc from the module prior to operation.
8. Safely resume normal operation.
Figure 2.4—Optional Module Installation
Master Plate
Tool Plate
Electrical Module
(9120-K19-M Shown)
Electrical Module
(9120-K19-M Shown)
(2) M3 Socket Head
Cap Screw
(2) M3 Socket Head
Cap Screw
2.10 Optional K Series Module Removal
Tools required: 2.5 mm hex key
1. If the Tool Changer is in service, place the Tool in a secure location.
2.
Uncouple the Master and Tool plates.
3. Turn off and de‑energize all energized circuits; for example, electrical, air, water, etc. If required, fully
disconnect these circuits.
4.
Remove the (2) M3 socket head cap screws using a 2.5 mm hex key. Note: To remove the module on the
Master, the Master plate might have to be removed. Refer to
Section 2.3—Master Plate Removal.
5. Remove the module from the Master and/or Tool plate.