Manual, Control Module, PROFINET, DL10
Document #9620-20-C-DL10-04
Pinnacle Park • 1031 Goodworth Drive • Apex, NC 27539 • Tel: 919.772.0115 • Fax: 919.772.8259 •
C-12
2.1.3 Ethernet 1 and Ethernet 2 LEDs
The Ethernet LEDs provide information about link status and activity on the ports of the integrated
Ethernet switch.
The Ethernet 1 (E1) LED displays the status of the robot side Ethernet port. The Ethernet 2 (E2)
LED displays the status of the tool side Ethernet port. The module status is indicated by the
specified LED colors in the following tables.
Table 2.6—Master Module Ethernet 1 (E1) LEDs
Status
LED
Note
No Link
Off
The Master module has no connection to the
Ethernet.
Link
Green
(solid)
The Master module is connected to the Ethernet
but there is currently no data exchange activity.
Active RX/TX
Red
(flashing)
Green
(solid)
There is sporatic data exchange activity with the
Ethernet.
PROFINET
connection
established
Red
(solid)
Green
(solid)
There is continuous data exchange activity with the
Ethernet.
Table 2.7—Master Module Ethernet 2 (E2) LEDs
Status
LED
Note
No Link
Off
The Tool module has no connection to the Ethernet.
Link
Green
(solid)
The Tool module is connected to the Ethernet but
there is currently no data exchange activity.
Active RX/TX
Red
(flashing)
Green
(solid)
There is sporatic data exchange activity with the
Ethernet.
PROFINET
connection
established
Red
(solid)
Green
(solid)
There is continuous data exchange activity with the
Ethernet.
2.1.4 Integrated Ethernet Switch
The Master module provides an integrated 2‑port Ethernet switch which supports the following:
• Transmission rate 100 MBit/s
• Interface type 100 BASE‑TX, isolated
• Half duplex/Full duplex
• Auto Negotiation
• Auto Crossover