Manual, Valve Adapters, Single Solenoid
Document #9620-20-C-Jxx Valve Adapters with a Single Solenoid-04
Pinnacle Park • 1031 Goodworth Drive • Apex, NC 27539 • Tel: 919.772.0115 • Fax: 919.772.8259 •
C-13
5.2.2 Filter Replacement
The inlet filter prevents particulates from entering the air supply to the Tool Changer or Utility
Coupler locking mechanism. If the filter is clogged it may affect the ability to lock and unlock the
Tool Changer. Check/replace the filter if there is a considerable reduction in unlocking speed.
Parts required:
Refer to Drawings
.
Supplies required:
Loctite 569
®
or similar
Tools required:
5/8 mm hex wrench
1. Place the Tool in a secure location.
2. Uncouple the Master and Tool plates.
3. Turn off and de-energize all energized circuits (for example: electrical, pneumatic, and
hydraulic circuits).
4. Disconnect the air supply to the filter.
5. Use a 5/8 hex wrench to remove the filter.
6. Replace clogged filter with new part:
a. Apply Loctite 569 to air supply port.
b. Use the wrench to thread the new filter into the valve adapter housing.
c. Tighten filter to 15 ft-lb.
7. Reconnect air supply to filter and tighten air supply line fitting. Torque should not
exceed 15 ft-lb.
8. After the repair is complete, safely resume normal operation.
Figure 5.3— Filter Replacement
Inlet Filter
Air Supply Port