Manual, Fluid/Air, FS2
Document #9620-20-D-FS2-04
Pinnacle Park • 1031 Goodworth Drive • Apex, NC 27539 • Tel: 919.772.0115 • Fax: 919.772.8259 •
D-12
5.2.3 Rubber Bushing Replacement
Parts required: Refer to
The rubber bushings seal the air passage from the Master module. If the bushing become cut or
damaged, they need to be replaced.
1. Remove damaged rubber bushing by grasping with fingers and pulling the bushing out of the
body.
2. Dip new bushing in water to aid in installation.
3. Insert the beveled (chamfered) end of the rubber bushing into the bore, leaving ribbed end of
the bushing facing outward.
4. Press the bushing in by hand until it is seated completely in the bore. If necessary, use a plastic
or rubber soft‑faced mallet to tap the bushings into place.
5. After the procedure is complete, resume normal operation.
Figure 5.5—Master Rubber Bushing Replacement
Rubber Bushing
9121-FS2-M
Master Module