Manual, Control Module, PROFINET, DL12
Document #9620-20-C-DL12-06
Pinnacle Park • 1031 Goodworth Drive • Apex, NC 27539 • Tel: 919.772.0115 • Fax: 919.772.8259 •
C-6
Figure 1.1—Modules
19-Pin Signal Contact
19-Pin Spring Signal Contact
and Rubber V-ring Seal
4-Pin Female D-coded
PROFINET Connector
4-Pin Female D-coded
PROFINET Connector
5-Pin Female M12
TSI Connector
(4) 3-Pin Female M8
RTL, Lock, and Unlock Connector
5-Pin Male Minifast
Power Connector
FE Ground Terminal Connection
5-Pin Female Minifast
Power Connector
Tool-ID
SF, Ethernet 2, BF,
Ethernet 1 LED's,
and Reset Switch
7-Pin Power Spring Contact
and Rubber V-ring Seal
7-Pin Power Contact
Valve Adapter Pressure Sensor Connector
4-Pin Female M8
Valve Signal Pin Block
FE Ground Terminal Connection
Valve Adapter Proximity Sensor Connector
3-Pin Female M8
Common Ledge
Mounting Feature
DL12 Tool Module
DL12 Master Module
1.2 Tool Module
The module has the following connectors:
•
(1) 5‑pin female M12 safety switch connector
•
(1) 4‑pin female M12 D‑coded PROFINET connector
•
(1) 4‑pin male minifast power connector
The module requires a JR4‑T tool adapter to align the Master and Tool modules, and mounts to the Tool
plate of the Tool Changer or Utility Coupler. PROFINET requires a FE ground, the Tool module provides a
M5 threaded hole that is passes FE ground to the customer tooling. The M5 set screw must be removed prior
to FE ground connection.
The module has a series of push button switches for setting of the Tool‑ID input. This allows the customer
to distinguish between the different tools that are being used in a robotic cell or on a production line. The
Tool‑ID is reported through the Master module bitmap. Refer to