Manual, F/T Sensor, Ethernet Axia
Document #9610-05-Ethernet Axia-09
Pinnacle Park • 1031 Goodworth Drive • Apex, NC 27539 • Tel:+1 919.772.0115 • Fax:+1 919.772.8259 •
15
3. Installation
WARNING:
Performing maintenance or repair on the sensor when circuits (for example:
power, water, and air) are energized could result in death or serious injury. Discharge and
verify all energized circuits are de-energized in accordance with the customer’s safety
practices and policies.
CAUTION:
Using fasteners that exceed the customer interface depth penetrates the body of
the sensor, damages the electronics, and voids the warranty. Refer to
for more information.
CAUTION:
Thread locker applied to fasteners must not be used more than once. Fasteners
might become loose and cause equipment damage. Always apply new thread locker when
reusing fasteners.
CAUTION:
Avoid damage to the sensor from electrostatic discharge. Ensure proper
grounding procedures are followed when handling the sensor or cables connected to the
sensor. Failure to follow proper grounding procedures could damage the sensor.
CAUTION:
Do not apply excessive force to the sensor and cable connector during
installation, or damage will occur to the connectors. Align the keyway on the sensor and cable
connector during installation to avoid applying excessive force to the connectors.
Keyway on the
cable connector.
Keyway on the
sensor connector.
3.1 Interface Plates
The sensor’s mounting side attaches to the robot arm, and the sensor’s tool side attaches to the customer
tool. If interface plates are required to adapt the sensor to the robot arm and customer tooling, ATI can
supply custom robot mounting and tool interface plates.
For technical information on the sensor’s mounting
features, refer to
CAUTION:
Incorrect installation of robot mounting and tool interface plates results in
the failure of the F/T sensor to function properly. Because the mounting and tool sides
of the sensor have identical bolt patterns, verify the robot mounting and tool interface
plates are installed correctly.
CAUTION:
The customer tool should only touch the tool side. If the customer tool
touches any other part of the sensor, it will not properly sense loads.