The display will then show the INTERNAL
IMBALANCE and SPL in the third field.
By turning the wheel until all the diodes for the
external position light up, the respective value will
also be displayed.
Now position the weight up to the gauge and use
this to position the weight on the wheel rim.
Continue to turn the wheel until all the diodes for
the external position light up in order to pinpoint
the second value. The respective value will then
also be displayed.
Next, position the weight on the gauge and use
this to position the weight on the wheel rim.
b)
Optimisation
-
It is possible to minimise the static imbalance of the wheel using the OPT function. The unbalance
of the wheel rim is evened out with the unbalance of the tyre.
After a balancing run, you can test the static
imbalance by pressing the F button.
If the imbalance is over 30 g, an optimisation
process is recommended.
Make a mark at the position of the valve on the
tyre, the entry cover of the balancing machine and
the wheel rim so that the mark lines up with the
valve.