® Copyright ATH-Heinl GmbH & Co. KG, 2013, All rights reserved. / Misprints and technical changes reserved / Issue: 09/2016
11
If soils do not comply with the requirements, there can evoke serious injuries to personal or damages to the lift.
Do
not install
the lift on
asphalt
or
soft concrete floor
.
There must be
no expansion joints or cuts
, which will break the continuity of the upper reinforcement.
Load capacity of intermediate ceilings must be checked by operator.
Place of installation
B1
1.000 mm
B2
1.000 mm
L1
appr. 2.800 mm
L2
appr. 2.800 mm
H
appr. 4.000 mm
Allowed working temperature:
10-50 °C
Max. allowed humidity:
≤80% bei 30
°C
Height above sea level:
≤
2000m
Power connection and ground cable (see technical data) is to be made in form of a plug device (socket and plug ) or a
fixed connection.
Necessary supply lines
See technical data
The lift is designed for an installation in dry rooms. The installation in
wet rooms
as well as
rooms with a risk of
explosion is not allowed.