6/16
CE
0537
= Valid production quality system approved and notified by VTT (Finnish Notified Body,
listed by EC)
= Certified for explosion hazardous areas
II
= Certified for use in areas excluding mines
2
= Equipment category (suitable for Zone 1&21 and Zone 2&22)
G
= Certification taking account explosion hazardous GASES
D
= Certification taking account explosion hazardous DUSTS
Explanation of marking for explosion hazardous area due to Gases (Ex e ib mb IIC T3
Gb):
Ex
= Certified for use in explosion hazardous areas
e
= Explosion protection method increased safety (of certain components)
ib
= Explosion protection method intrinsic safety (of certain components)
mb
= Explosion protection method encapsulation (encapsulating ignition sources e.g.
electronic ballast)
IIC
= Equipment group (including explosion hazardous areas of IIA, IIB and IIC gases)
T3
= Maximum inside temperature of the unit is 200 °C (within the ambient temperature range
of -20°C - +40°C)
Gb
=
Explosion Protection Level (EPL) marking for “HIGH” level of protection. Equipment for
explosive
GAS
atmospheres, which is not a source of ignition in normal operation or during
expected malfunctions
Explanation of marking for explosion hazardous area due to Dusts (Ex t IIIC T 90 C Db):
Ex
= Certified for use in explosion hazardous areas
t
= Explosion protection method “protection by enclosure”
IIIC
= Equipment group for all dusts
T 90 C
= Maximum OUTSIDE surface temperature of the unit is 90 °C (within the ambient
temperature range of -20°C - +40°C)
Db
= Explosion Protection Level (EPL) marking for “HIGH” level of protection. Equipment for
explosive
DUST
atmospheres, which is not a source of ignition in normal operation or during
expected malfunctions
1.3 Standard unit construction
The following list familiarizes you with some common unit features important to recognize.
End parts
: Flexible, plastic-made end parts ensure shock-absorbing and harmless contact to
sensitive and hard surface in case the luminary drops to the ground even from high position.
Light construction affects the total weight of the unit itself.