3.5 Connection to the supply 

It is recommended that the unit is first connected to the mains / transformer before entering the explosion 
hazardous area. Potential equalization should be arranged by the operator prior entering explosion hazardous 
area. 
 
Slam® Hornet-units with 2-pole supply (without bonding connection) can be taken to explosion hazardous area 
without connecting it to the supply first. 

3.5.1 Requirements for supply (electricity) 

The following main requirements should be taken into account: 
 

Supply voltage

: Variation may be m/- 6% from the value stated in the unit type label. 

Current

: Maximum current of the system is 16 A. 

Frequency

: Standard 50 Hz if not otherwise stated in the type label. 

Fuse protection

: The supply has a fuse with a breaking capacity of at least 1500 A 

 
Please observe the type label for further data. 
 

3.6 Adding accessories to Slam®  Hornet 

Atexor provides a number of different accessories but in case you afterwards want to add accessories of your 
own for the Slam® Hornet Emergency

–unit, please note the following points: 

 

1.  The user is fully responsible for the use of the equipment including service and maintenance 

 

2.  In case of adding accessories the following is mandatory 

 

a.  The construction of the certified unit shall not change 
b.  The IP 

–class of the unit shall not decrease 

 

3.  The static electricity is taken account (e.g. electrostatic bonding) 

 
In case you do not want to do your own risk assessment for the accessories please view the whole range of 
accessories at  

http://www.atexor.com

 

3.7 Linking in Series  

Certain Slam® Hornet -units may be equipped with Ex 

–certified socket in the factory. Sockets are considered as 

one option so they are added to the unit upon customer’s special request. 
 
In-built sockets are recommended when the illuminated area is notably large, complex or not enough wiring 
points are available. Linking the units in series save time, amount of cable and provide an opportunity to build a 
chain of lights to provide enough illumination in the darkness. 
 
When linking Slam® Hornet Emergency 

–units together, please take the following steps: 

 

1)  If using transformer, ensure its condition and capability to supply correct amount of voltage and current 
2)  Connect the first unit outside the Ex 

–area 

3)  Then connect the other luminaries to each other one by one 

Summary of Contents for Slam Hornet Emergency 18+40W

Page 1: ...ication N o VTT 08 ATEX 030X Thank you for choosing Slam Hornet Emergency portable work light for your job site Purpose of this manual is to provide you all the necessary safety and product informatio...

Page 2: ...2 16...

Page 3: ...p IIA IIB or IIC in accordance with Equipment group IIA IIB or IIC 9 2 1 4 Temperature class of the equipment 9 2 1 5 Environmental criteria 9 3 Operating instructions 10 3 1 Personnel 10 3 2 Before f...

Page 4: ...16 4 3 Testing 14 4 4 Repair report 14 4 5 Periodical testing of CentaurSlam Hornet Emergency 14 4 6 More information about the use of Electrical Apparatus for Explosive Gas Atmospheres 15 Helpdesk 1...

Page 5: ...tificate for special conditions of safe use of the equipment Special conditions of safe use specifies Ambient temperature can be 20 C 40 C without Ex socket With Ex socket as specified for the used so...

Page 6: ...of 20 C 40 C Gb Explosion Protection Level EPL marking for HIGH level of protection Equipment for explosive GAS atmospheres which is not a source of ignition in normal operation or during expected mal...

Page 7: ...g appropriate help for the user to complete his job Cable Standard cable of the Slam Hornet series is H07BQ F This cable has polyurethane PUR outer sleeve PUR withstands well chemicals as well mechani...

Page 8: ...can not be identified visually Testing voltage applied is 2130VDC Maximum leakage current is 5mA Test of expected use of equipment The luminary is subjected to shaking and vibration to see that all th...

Page 9: ...o three different groups IIA IIB and IIC Further information about the substances can be found from EN 60079 10 Slam units mentioned in this instruction are Equipment group IIC 2 1 4 Temperature class...

Page 10: ...ts or defects on the unit are noticed it is prohibited to take such a unit into Ex area until the corrective actions have been made 3 4 Special attention on 2 pole use 24 V or 42 V Certain Slam Hornet...

Page 11: ...ts 1 The user is fully responsible for the use of the equipment including service and maintenance 2 In case of adding accessories the following is mandatory a The construction of the certified unit sh...

Page 12: ...rmful and may damage the ballast permanently when subjected to excessive peaks continuously If fluorescent tubes are flickering when the units are chained up it may be due to excessive linking This ma...

Page 13: ...Inspection Maintenance 4 1 After Use Take the following steps after the Slam Hornet Emergency unit has been taken out from Ex area 1 Clean the unit with a damp cloth do not use detergents or solvents...

Page 14: ...returning the repaired unit back to operation Below mentioned tests shall be done in addition to the tests specified in EN 60079 19 PE resistance test High voltage test 500 VDC between Phase Neutral a...

Page 15: ...tandards of the day Please study at least the following standards EN 60079 14 Electrical installations in hazardous areas EN 60079 10 Classification of hazardous areas EN 60079 17 Inspection and maint...

Page 16: ...16 Helpdesk Under any doubt or question please contact your local distributor or the manufacturer Contact details Phone 358 20 734 3250 Fax 358 20 734 3299 Email info atexor com Web http www atexor c...

Reviews: