5/16
1.
Introduction to Slam® Hornet Emergency
(Certification N:o VTT 08 ATEX 030X)
This instruction manual guides you through the process of selecting and adopting Slam® Hornet Emergency
work light at your work site. The manual regards the following Slam® Hornet Emergency type:
1.1 Technical data
Slam® Hornet Emergency 18W+40W
(later CSHEM)
Dimensions / mm
Product model
L
Ø
Slam® Hornet Emergency 18+40W
1020
115
1.2 Certification of equipment
The Slam® Hornet
–series has been designed, tested and certified (according to ATEX) for
portable use. There is “X” –mark in the certificate for special conditions of safe use of the
equipment. Special conditions of safe use specifies:
Ambient temperature can be
– 20°C --- + 40°C without Ex-socket
With Ex-socket as specified for the used socket but within
– 20°C --- + 40°C
“ib”-marking is for internal protection of the switch in the emergency supply circuit. There is NO need for
Exi assosiated apparatus in the supply of the luminaire
The equipment is to be used properly and according to its ratings, documentation and local
applicable laws. Local, national certificates of these units may exist outside the region of EU.
The aforementioned Slam® Hornet
–types are certified as follows. You may find brief
explanation of certificate beneath:
CE
0537
II 2 G
Ex e ib mb IIC T3 Gb
II 2 D
Ex t IIIC T 90 C Db
IP 66
Summary of Contents for Slam Hornet Emergency 18+40W
Page 2: ...2 16...