4.2 Maintenance 

 
The following procedure should be taken in case the Slam®Hornet unit needs to be repaired: 
 

1)  Maintenance may be carried out only outside Ex 

–area 

 

2)  Person responsible for maintenance should have been trained the basics of explosion-protection as well 

electricity. Please refer e.g. EN/IEC 60079-19 for further details. 

 

3)  Only  original  spare  parts  from  the  manufacturer  should  be  used.  Please  note  that  there  are  no 

components in this unit which can be repaired by using glue, silicone or any other similar method. 

4)  The  dissipation  feature  (antistatic)  on  transparent  parts  of  Slam®Hornet  may  be  damaged  because  of 

external  affects  like  solvents  or  chemicals  or  mechanical  stress.  In  case  the  surface  of  the  PC-tube  is 

damaged  in  one  area  greater  than  100  cm

2

  the  part  has  to be  changed.  The  surface  resistance  of  the 

transparent parts has to be between 1 MΩ - 1 GΩ. Please contact Atexor Oy in case You need a simple 
measuring device, which is needed for measuring surface resistance of the PC-tube. 

 

5)  Maintenance  instructions  with  exploded-view  diagram  and  spare  parts  list  are  available  at  your  local 

distributor and the manufacturer. Please, when requesting maintenance instructions with exploded-view 

diagrams, include the model and serial number of the product. 

 

4.3 Testing 

 
Tests are to be done according to EN/IEC 60079-19 until returning the repaired unit back to 
operation.  Below  mentioned  tests  shall  be  done  in  addition  to  the  tests  specified  in  EN/IEC 
60079-19.  For  acceptance  criteria  please  refer  to  the  original  test  report  of  the  equipment 
which is included in the delivery 
 

 

PE 

–resistance test 

 

High-voltage test (500 VDC between Phase& Neutral against P/E conductor) 

 

Operational test 

 

Test of expected use (vibrations, shaking) 

 

Proper testing ensure safe operation of repaired equipment. 
 

4.4 Repair report 

 
The  operator  is  responsible  for  keeping  up  to  date  record  of  the  condition  of  his  equipment 
(EN/IEC  60079-14).  Ensuring  the  availability  of  this  important  information  each  repair 
procedure should be written down in repair report according to EN/IEC 60079-19. 
 
This report should reveal at least: 

Summary of Contents for Slam Hornet 1 LED A

Page 1: ...08 ATEX 066 or IECEx VTT 12 0009 Thank you for choosing Slam Hornet portable work light for your job site Purpose of this manual is to provide you all the necessary safety and product information to...

Page 2: ...IA IIB or IIC in accordance with Equipment group IIA IIB or IIC 8 2 1 4 Temperature class of the equipment 9 2 1 5 Environmental criteria 9 3 Operating instructions 10 3 1 Personnel 10 3 2 Visual Insp...

Page 3: ...et 2 LED Slam Hornet Linear 2x18W Slam Hornet Linear 2x36W Slam Hornet Linear 2 LED Dimensions mm Product model L Slam Hornet 1x18W 335 115 Slam Hornet 1x36W A Slam Hornet 1 LED A 540 115 Slam Hornet...

Page 4: ...sion hazardous GASES D Certification taking account explosion hazardous DUSTS Explanation of marking for explosion hazardous area due to Gases e g Ex emb IIC T3 Gb Ex Certified for use in explosion ha...

Page 5: ...ation or during expected malfunctions 1 3 Standard unit construction The following list familiarizes you with some common unit features important to recognize End parts Flexible plastic made end parts...

Page 6: ...nts of own Socket Optional in built sockets receptacles for linking the Slam Hornet units in series apart from CSH118 Other common accessories Antistatic protective film for PC tube against chemical s...

Page 7: ...5 ohm High voltage test electrical strength The purpose of this test is to measure leakage current trough insulation Vital test for revealing broken components or similar failures which can not be ide...

Page 8: ...t category For explosion hazardous areas there are three equipment categories Category 1 product is suitable for use in Zones 0 1 and 2 20 21 and 22 Category 2 product is suitable for use in Zones 1 a...

Page 9: ...ntioned in this instruction are Temperature Class T4 GASES Slam units with fluorescent tube and LED modules mentioned in this instruction are having maximum surface temperature of 90 C DUSTS 2 1 5 Env...

Page 10: ...be used together with step down transformers Using Slam Hornet unit with transformers of 2 pole socket outlets without earthing bonding imposes certain extra requirements for the unit itself All the e...

Page 11: ...king capacity of at least 1500 A Earth Leakage Circuit Breaker ELCB It is recommended to use a supply with 30 mA ELCB Please observe the type label for further data Luminaires for 110 VAC or 230 V sup...

Page 12: ...is only for chaining Slam Hornet units 5 Fix them with accessories you have selected 6 Take the chain into Ex area Amount of lights which may be connected with each other depends on the supply voltage...

Page 13: ...net control gear protects itself against excessive voltage drops numerous linking by switching itself off If too many units are connected to the chain some units of the chain will switch off You may s...

Page 14: ...needed for measuring surface resistance of the PC tube 5 Maintenance instructions with exploded view diagram and spare parts list are available at your local distributor and the manufacturer Please wh...

Page 15: ...Gas Atmospheres Please observe the requirements of the valid standards of the day Please study at least the following standards EN IEC 60079 14 Electrical installations in hazardous areas EN IEC 60079...

Page 16: ...16 Helpdesk Under any doubt or question please contact your local distributor or the manufacturer Contact details Phone 358 20 734 3250 Fax 358 20 734 3299 Email info atexor com Web http www atexor c...

Reviews: