Resetting the short-circuit protection:
After the LED bulb has been replaced, it may be necessary to reset the short-circuit protection of
electronics by keeping the lamp in the charger stand for a while. Resetting should also be done when
larger components have been replaced.
Note that the EX classification of the MICA IL-80 ATEX LED lamp requires that only original MICA
spare parts are used with the lamp. The L200Ex bulb of the MICA IL-80 ATEX LED lamp may not
be replaced with other bulbs. You can influence the shape of the light beam by selecting a narrow or
medium-width reflector.
NOTE! Always indicate the type and serial number of the lamp/charger when ordering spare parts!
MICA IL-80 ATEX LED SPARE PART NUMBERS:
1
M02912_X
IL-80 LED battery pack
2
M03464_X
IL-80 electronics unit (circuit board, carrier unit)
M03463_X
IL-80 EM electronics unit (circuit board, carrier unit)
Note: When replacing electronic units,
the old unit must be returned to the manufacturer!
3
M00957
Charger contact unit (ILC4)
4
M03356
IL-80 ATEX LED lamp switch
5
M00419
IL switch rubber cover
6
MH0303_1
IL Ex switch cover plate unit
7
MH0307_1
IL reflector, narrow
8
MH0304_1
L200Ex LED bulb unit
9
M00945
O ring
10
M01297_X
IL glass lens
11
M0104_4
IL-80 ATEX LED closing ring
70706
IL-80 ATEX strap
OPERATING TIMES:
Partial power: 21 h
Full power: 10 h 30 min
1
2
7
8
9
10
11
6
5
4
3