background image

Resetting the short-circuit protection:

After the LED bulb has been replaced, it may be necessary to reset the short-circuit protection of 

electronics by keeping the lamp in the charger stand for a while. Resetting should also be done when 

larger components have been replaced.

Note that the EX classification of the MICA IL-80 ATEX LED lamp requires that only original MICA 

spare parts are used with the lamp. The L200Ex bulb of the MICA IL-80 ATEX LED lamp may not 

be replaced with other bulbs. You can influence the shape of the light beam by selecting a narrow or 

medium-width reflector.

NOTE! Always indicate the type and serial number of the lamp/charger when ordering spare parts!

MICA IL-80 ATEX LED SPARE PART NUMBERS:

1  

M02912_X  

IL-80 LED battery pack

2  

M03464_X  

IL-80 electronics unit (circuit board, carrier unit)

 

M03463_X  

IL-80 EM electronics unit (circuit board, carrier unit)

 

 

 

Note: When replacing electronic units,  

 

 

 

the old unit must be returned to the manufacturer!

3  

M00957  

Charger contact unit (ILC4)

4  

M03356  

IL-80 ATEX LED lamp switch

5  

M00419 

IL switch rubber cover

6  

MH0303_1  

IL Ex switch cover plate unit

7  

MH0307_1  

IL reflector, narrow

8  

MH0304_1  

L200Ex LED bulb unit

9  

M00945  

O ring

10  

M01297_X  

IL glass lens

11  

M0104_4  

IL-80 ATEX LED closing ring

 

70706    

IL-80 ATEX strap

OPERATING TIMES:

Partial power: 21 h

Full power: 10 h 30 min

1

2

7

8

9

10

11

6

5

4

3

Reviews: