Appendix
191
2. IP – Set IP address
IP
Old IP address: 192.168.0.60
New IP address:
3. LO – Load connections from profile
LO 01
Load profile 01 OK.
4. PW – Change password
PW
Old password: ********
New password:
5. RI – Read what input is connected to
nn
output
RI 01
Input port 02 04 08 is connected to output port 01
6. RO – Read what output is connected to
nn
input
RO 01
Output port 02 is connected to input port 01
7. SB – Set serial port baud rate
SB 96
Serial port baud rate is set to 9600
8. SS – Switch input to specified output
SS 01,03
Switch input 01 to output 03 (00: Local Port)