Chapter 6. CLI Commands
81
Setting the Baud Rate
To set the baud rate of RS-232 serial transmission for VE8900 / VE8950 /
VE8952 devices, type the command in this format:
baud + a<port> | i<port> | o<port> + <baud_rate> + \r\n
Examples
To set the baud rate of a VE8900 transmitter with the device ID of 3 to
115200, type
baud a3 115200
To set all VE8900 / VE8950 receivers to default, type
baud o* 9600
Control
Description
a<port>
Indicates the MAC ID or the IP address of the target VE8900 / VE8950
/ VE8952 transmitter or receiver.
i<port>
Indicates the device ID, MAC ID, or the IP address of the target input
source (VE8900 / VE8950 / VE8952 transmitter) device. Use an
asterisk (*) to target all VE8900 / VE8950 / VE8952 transmitters in the
environment.
o<port>
Indicates the device ID, MAC ID, or the IP address of the target output
(VE8900 / VE8950 / VE8952 receiver) device. Use an asterisk (*) to
target all VE8900 / VE8950 / VE8952 receivers in the environment.
<baud_rate>
Indicates the baud rate to which you wish to set the target devices.
Valid inputs include
9600
,
19200
,
38400
, and
115200
.
\r\n
Ends the command.