CS1942DP / CS1944DP
2/4-Port USB 3.0 4K DisplayPort
Dual Display KVMP
TM
Switch
RS-232 Commands
V1.0
User Manual
www.aten.com
Page 1: ...CS1942DP CS1944DP 2 4 Port USB 3 0 4K DisplayPort Dual Display KVMPTM Switch RS 232 Commands V1 0 User Manual www aten com ...
Page 2: ...io or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult...
Page 3: ...HyperTerminal application For detailed instructions and information about each of the commands provided in this manual please refer to the CS1942DP CS1944DP user manual Setup Install a HyperTerminal application on a computer that is not part of the installation which will be used to control the switch via the RS 232 connection HyperTerminal applications can be download from the Internet and many o...
Page 4: ...an establish a HyperTerminal session using the instructions below 1 Open the HyperTerminal application and configure the port settings for COM1 port then click OK Bits per Second 19200 Data Bits 8 Parity None Stop bits 1 Flow Control None 2 After configuring the port settings you must enable serial control on the switch by typing the command Open Enter ...
Page 5: ...eys will be disabled until the serial connection is closed For detailed information about the controls listed in this guide please refer to the CS1942DP CS1944DP user manual Verification After entering a command a verification message appears as shown below at the end of the command line as follows With all commands in the sections that follow Each command string can be separated with a space The ...
Page 6: ...ose command or after 2 minutes if no command is sent The default value is close Use the Formula to set Parameters to create a Command Formulas Command Enter Parameters Open Close RS 232 Link Command The available formulas for the Open Close RS 232 Link commands are as follows 1 Command Enter For example to open the RS 232 link between the computer and CS1942DP CS1944DP type the following open Ente...
Page 7: ...tch Port Commands Some available formulas for the Switch Port commands are as follows 1 Command Control Enter For example to switch to port 2 type the following sw i02 Enter Note The Control command can be skipped and the default value will be used Command Description sw Switch Port Command Control Description ixx Input Port Number x 01 02 CS1942DP 01 04 CS1944DP Enter Description Enter Enter and ...
Page 8: ...ormula Command Control Enter Parameters Set Baud Rate Commands Some available formulas for the Set Baud Rate commands are as follows 1 Command Control Enter For example to set the baud rate to 19200 type the following baud 19200 Enter Command Description baud Baud Rate Command Control Description 19200 Set baud rate to 19200 Default 38400 Set baud rate to 38400 9600 Set baud rate to 9600 Enter Des...
Page 9: ...llows 1 Command Control Enter For example to change the keyboard language layout to Japanese type the following layout jp Enter 2 Command Control Enter For example to change the keyboard language layout to French type the following layout fr Enter Command Description layout Keyboard Language Layout Command Control Description en Change the keyboard language layout to English fr Change the keyboard...
Page 10: ...ands Some available formulas for Hotkey Setting commands are as follows 1 Command Control Enter For example to change the HSM invoke key to Num Lock type the following hotkey num Enter 2 Command Control Enter For example to change the HSM invoke key to Ctrl F12 type the following hotkey f12 Enter Command Description hotkey Hotkey Setting Command Control Description num Change the HSM invoke key to...
Page 11: ...or Hotkey Switching commands are as follows 1 Command Control Enter For example to change the hotkey switching mode to Scroll Scroll type the following switch scroll Enter 2 Command Control Enter For example to change the hotkey switching mode to Ctrl Ctrl type the following switch ctrl Enter Command Description switch Hotkey Switching Command Control Description scroll Change hotkey switching key...
Page 12: ...eate a Command Formulas Command Control Enter Parameters USB Reset Command The available formula for the USB Reset command is as follows 1 Command Control Enter For example to reset the USB connection type the following usbreset on Enter Command Description usbreset USB Reset Command Control Description on Enable USB reset connection Enter Description Enter Enter and send out command ...
Page 13: ...mulas Command Control Enter Parameters Restore Default Value Command The available formula for the Restore Default Settings command is as follows 1 Command Control Enter For example to restore all CS1942DP CS1944DP settings back to the default type the following reset on Enter Command Description reset Restore Default Settings Command Control Description on Enable restore default values Enter Desc...
Page 14: ... Command Formulas Command Control Enter Parameters Firmware Upgrade Command The available formula for the Firmware Upgrade command is as follows 1 Command Control Enter For example to enable firmware upgrade mode type the following upgrade on Enter Command Description upgrade Firmware Upgrade Command Control Description on Enable firmware upgrade mode Enter Description Enter Enter and send out com...
Page 15: ...KVM Status command is as follows 1 Command Control Enter For example to display the CS1942DP CS1944DP s configuration status type the following status on Enter A message similar to the one below will then appear hotkey numlock scrolllock scrolllock os setting pc keyboard emulation enabled disabled keyboard layout English mouse emulation enabled disabled monitor re detection enabled disabled Comman...
Page 16: ...CS1942DP CS1944DP RS 232 Commands 16 ...