background image

KK-INC.006 18.01.19 Rev No:1 

Signal 

M12 Socket 

Cable 

V+ (12..24VDC) 

Pin 1 

Red 

Output 1 (0.1-10VDC / 4-20mA) (X axis) 

Pin 2 

Yellow 

GND (0V) 

Pin 3 

Black 

Output 2 (0.1-10VDC / 4-20mA) (Y axis) 

Pin 4 

Green 

Reset 

Pin 5 

Pink 

 

 
 
 
 
 
 
 

 
 
 
 
 
 

 

 

 
 
 
 

 
 
 
 
 
 
 
 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

The installation of the product is carried out by the customer who purchases the product, according to the wiring diagrams, 
installation information, etc. in this manual. 

Maintenance and repair should be done by the technicians authorized by the manufacturer firm. 

There must be minimum distance between the sensor and control unit. Avoid additions except the suitable connector unless 
it needs. 

Keep  away  the  sensor  cable  from  as  high  power  energy  cables,  contactor,  motor,  switched  power  supplies,  inductive  and 
capacitive noisy supplies. 

Not  to  damage  the  sensor,  supply  directions  and  voltage  must  be  paid  attention.  Don’t  energize  before  all  connections 
completed. 

Transport and storage should be at their original packaging and an ambient temperature of -30°C / +70°C in such a way that 
they will not be exposed to dust, humudity, impact, vibration, falling or water. 

Chemicals  such  as  alcohol,  thinner  etc.  should  not  be  used  for  cleaning  the  product.  The  product  should  be  wiped  with  a 
damp cloth. 

The product may be damaged and may become unusable if used outside of the specifications in the user manual. 

 

 

 

INC 210 (Analog Output) 

      

ANGLE SENSOR USER MANUAL 

 

WARNINGS 

 

 

ELECTRICAL CONNECTION 

 

DETERMINING THE 0° POINT OF SENSOR 

Pin 5 (pink cable) and pin 3 (black cable) are short-circuited for about 2 seconds and then disconnected.

 

Thus, the sensor 

recognizes that the  position is 0 °. If the same operation is repeated a second  time, the sensor is reset to the factory 
settings. 
During the operations, the sensor position should be kept constant for approximately 4 seconds. 

 

M12 - 5 PIN MALE 

SOCKET 

 

* Output 2 is only used on two-axis models. On single-axis models, Pin 4 (green 
cable) is empty. 
* On single output models, 1 pcs M12 5 pin male socket is used as standard. 
* Redundant models have two outputs. 1 pcs M12 5 pin male ve 1 pcs M12 5 pin 
female socket is used as standard.  

Different socket models can be requested optionally.

 

 
 

GENERAL INFORMATIONS 

 

INC 210 series angle sensors are the sensors that show the angle of rotation of objects 
standing  perpendicular  to  the  earth.  Angle  measurement  information  between  0°-360° 
can  be  taken  from  these  sensors.  These  sensors  with  0.1-10VDC  voltage  output  or  4-
20mA current output option, can  take measure ment with ±0.1° accuracy. Thanks to its 
compensated axis sensitivity, the effect of the axes on each other is minimized. 
 
These sensors, especially used in machine and crane industries, can operate in outdoor

 

environments  with  their  high  IP  protection  classes.  Optionally,  sensors  with  redundant 
output can be produced. 

 

M12 - 5 PIN 

FEMALE SOCKET 

 

Summary of Contents for INC 210 Series

Page 1: ...tions in the user manual INC 210 Analog Output ANGLE SENSOR USER MANUAL WARNINGS ELECTRICAL CONNECTION DETERMINING THE 0 POINT OF SENSOR Pin 5 pink cable and pin 3 black cable are short circuited for about 2 seconds and then disconnected Thus the sensor recognizes that the position is 0 If the same operation is repeated a second time the sensor is reset to the factory settings During the operation...

Page 2: ...lts and nuts Warning All welding work in the relevant area must be completed before the product is installed Otherwise the device may be damaged during the welding process and in this case it will be out of warranty 0 360 DIMENSIONS in mm MEASUREMENT AXIS AND OUTPUT DIAGRAM GRAFİĞİ MECHANICAL MOUNTING Analog Signal Output ...

Page 3: ...ocket redundant models Measurement Range 2 360 0 360 180 0 180 Output Signal Direction CW Clockwise CCW Counter Clockwise Output Type No code Single Output Dual Redundant output 1 The supply voltage is 12 24VDC for 4 20 mA output models and 15 24VDC for 0 10 VDC output models 2 Optionally different measurement values between 0 360 can be requested You should specify your non standard measurement v...

Page 4: ...Bulvari No 67 34956 Tuzla Istanbul TURKEY TEL 90 0216 399 44 04 FAX 90 0216 399 44 02 E mail info ateksensor com Disposal of Packagings Packaging materials consist of recyclable materials For providing recycling please dispose waste packagings to collecting points of authorized recycling facilities Disposal of E Waste This device is in conformity with WEEE Directive and consists of recyclable mate...

Page 5: ...SP Brazil Brasil Phone Telefone 55 16 3371 0112 55 16 3372 7800 Internet www metrolog net metrolog metrolog net Metrolog Controles de Medição Atek Sensor Technology A S Tuzla Kimya Sanayicileri Org San Bolg Melek Aras Bulvari No 67 34956 Tuzla Istanbul TURKEY Tel 90 216 399 44 04 Fax 90 216 399 44 02 www ateksensor com info ateksensor com ...