System Functionality
411
© 2017, ATEÏS, member of PAX ProAV Group
Step 8: Press the zone button that its LED is flashing to start to record, the recording time will be
ended by the duration time you set at Step 6. If you want to stop the message earlier, click the
zone button again or apply 1A00 command.
4.5.2.4
Log Loading
The Modbus client also allows to read all the logs of IDA8 system. See the following steps:
Step 1: Set the Modbus address as 40026, this indicates which IP address of Ateis-Net will be read.
Note: The IP address which is corresponded to the number is based on the hex code For
example, set the code as 0101, this indicates Ateis-Net(1,2);set the code as 2020, this indicates
Ateis-Net(32,32).
Step 2: Proceed the Modbus command: 8000/8001/8002/8003.
Step 3: Now Modbus client can read the IDA8 logs from the address range of 58588~59091.
4.6
User Management
User management ensures the security for accessing system resources and operations. Click [View > User
Management] to open the [User Manager Settings] window.
There are two tabs in [User Manager Settings] window: [Levels] and [Accounts].
Levels: Set the user level for accessing the system action. There are four default user levels
(Administrator/Power User/User/Operator) used by most applications which need authorized
requirement.
Accounts: Allow to create/delete/edit user account with different access level.
4.6.1
User Levels
Set the user level for accessing the system action. There are four default user levels(Administrator/Power
User/User/Operator) used by most applications which need authorized requirement.