Preset:
here you can specify the preset to be loaded
8.18.3.2
Logic Output
As described before, DIVA has 8 output channels that can be commanded by several trigger type.
When using the Logic Output Event, you can associate to a trigger the closing of an output.
•
Type:
displays the type of event that is created, in this case Load Preset
•
Name:
here you can specify a name for the event created
•
Attrib:
here you can choose between security event or not. See
about the security option
_________________________________________
•
Next Event:
you can specify an event that will be started as soon as this event has finished
_________________________________________
•
Active at Start:
Ticking this option allows user to close an output contact (Logic Output channel)
in two different manner. Static will close it until the event stop and Pulse will generate a closing
pulse whose length can be defined from 50 to 60000 ms.
•
Active at Stop:
This option is used to create a closing contact pulse when the event is finished.
The length of the pulse can be defined from 50 to 60000 ms.
To learn more about output relay, please read the
.
_________________________________________
•
Logic Output:
here you can specify which output(s) you want to close when a trigger has been
detected.
Ateïs International
Ch. du Dévent, 1024 Ecublens, Switzerland.
Phone : +41 21 881 25 10
66