Configuration
93
© 2019, ATEÏS, member of PAX ProAV Group
amplifier (by its ID). The default setting of AMP1 is to use the [int. AMP] on BTQ-VM4/VM8/
VM8W1/VM8W2; and the BTQ-SL8 can choose either [int. AMP] or [external AMP]. Then
choose the power wattage of controller from 240W/250W/480W/500W options, and set the
power wattage of [external AMP] on AMP1 channel.
AMP2---power: Choose a ID to identify the connected external amplifier for BTQ-VM4/VM8/
VM8W1/VM8W2/SG8/SL8. And set the power wattage of [external AMP] on AMP2 channel.
If no external amplifier is connected on the system, please choose [--] option.
Redundant loop: Enable this option if DPM remotes are connected to the main controller via
.
5.1.6.1.4.1 Application1: economic type
The internal amplifier in the main controller can share power amplifier with secondary local unit(s).
Equipment
o
One BTQ-VM850 main controller unit.
o
One BTQ-SL8 secondary unit.
Web browser setting
Type
AMP1
AMP1 Power
AMP2
AMP2 Power
VM8 (with built-in amp)
Int.
500
-
-
SL-1
Int.
Connection
5.1.6.1.4.2 Application2: medium scale type
This application is used for multiple zones such as shopping mall or several floors building, which
require to use additional amplifier to play the message, chime etc.
For example, the first amplifier (internal amp of main controller) will be used to play the background
music for all the floors, and the external amplifier will be used for general paging for specific floors
while the background music by using the internal amplification can be continued to play.
Equipment
o
One BTQ-VM850 main controller unit.
o
Two BTQ-SL8 secondary units.
o
One external power amplifier.
Web browser setting
Type
AMP1
AMP1 Power
AMP2
AMP2 Power
VM8 (with built-in
amp)
Int.
500
1
user defined
BTQ-SL8(1)
Int.
2