background image

1. Termination      

Connection

2. Signal Source 

Connection

7. Remote 

operation

5. System is On

6. IP Address 

setting

3. Ethernet 

Connection

4. Power up

Quick Start Guide/Model 2162

1. 

Connect an 

appropriately rated 
50 Ω termination to 
the 7/16” RF output 
connector. This 
power amplifier is 
capable of 
generating > 1kW of 
RF power. Failure to 
properly terminate 
the RF output can 
result in serious 
injury to personnel.

2. 

Connect a 

suitable signal 
source to the N-type 
RF Input connector. 
Nominal input power 
is 0 dBm.

If sample port is not 
used, terminate with 
an SMA 50 ohm load.

3.

Using standard Ethernet cabling,

connect both the 2162 system and an
external PC to an Ethernet switch.
This will allow access to the system’s
embedded

web GUI

and

the

UDP/IP

interface.

This is required to access full system
capability. Without this connection the
system can only be operated with the front
panel LCD screen, using factory settings of
ALC operation at full RF output power.
Remote operation through an external PC is
required to change operational modes and
power settings, and to view advanced
diagnostics.

See Step 7 for details on setting up the
remote

web

interface.

See

operating

manuals for details on UDP/IP interface.

4a.

Connect the ground stud to the

equipment enclosure's earth ground points.

4b.

Connect a wired AC mains connector

Amphenol P/N 97-3106A20-19S or equivalent
Connector Pinout
Pin A -- Neutral
Pin B -- Load
Pin C – Ground
System is rated to operate with an input
voltage range of 180-260VAC 47-63 Hz.
Maximum AC power consumption at 1 kW RF
output is 6kW.
A customer furnished circuit breaker upstream
to the system is required.

5.

Flip the circuit breaker to the

UP position. The internal fans will
turn

on

in

approximately

30

seconds. The single screen front
panel LCD screen will appear when
the system is ready for operation.
(~1.5 minutes). RF input required:
0 dBm +/- 5 dB