background image

ATTENTION !

Installing the LCD replacement is on your own risk! Your LYNX-II could be damaged,
if you are not able to do this modification!

Liability impossible!

Required materials:
LYNX-kit, VGA connector with screws, 18 wires round about 20 cm (8 inches) length 

(IDE cable)

1. Step: Remove not needed Parts and 5 Volt check

ATTENTION !

Make sure that all power is 

off

. Disconnect 

ALL

 cables.

1. Remove 

VR1

 trim potentiometer (if VGA connector is needed)

2. Remove 

L17

 coil

3. Remove 

Q13

 and 

Q14

 transistors

4. Remove 

C55 

and 

C56

 capicitors

5. Remove 

T1

 power module

!!! Now check the 5 Volt with a voltmeter on 

VCC point 

(see 3rd step). If the

voltage exceeds 5.45 Volt, repair your LYNX ! Otherwise the LYNX mod will
be 

damaged

 !!!

2. Step: VGA connector (if needed)

After that you solder the other side of
the wires to the LYNX mod.

 

Connect the pins 6, 7 and 8 together.
Solder 6 wires to the pins 1, 2, 3, 13,
14 and (6, 7, 8) to the VGA connector.

LYNX-II  LCD Replacement MOD REV2.0

(see picture below)

!!! Use hot glue for the internal screws of VGA connector. Otherwise the screws may cause short circuit !!!