ATTENTION !
Installing the LCD replacement is on your own risk! Your LYNX-II could be damaged,
if you are not able to do this modification!
Liability impossible!
Required materials:
LYNX-kit, VGA connector with screws, 18 wires round about 20 cm (8 inches) length
(IDE cable)
1. Step: Remove not needed Parts and 5 Volt check
ATTENTION !
Make sure that all power is
off
. Disconnect
ALL
cables.
1. Remove
VR1
trim potentiometer (if VGA connector is needed)
2. Remove
L17
coil
3. Remove
Q13
and
Q14
transistors
4. Remove
C55
and
C56
capicitors
5. Remove
T1
power module
!!! Now check the 5 Volt with a voltmeter on
VCC point
(see 3rd step). If the
voltage exceeds 5.45 Volt, repair your LYNX ! Otherwise the LYNX mod will
be
damaged
!!!
2. Step: VGA connector (if needed)
After that you solder the other side of
the wires to the LYNX mod.
Connect the pins 6, 7 and 8 together.
Solder 6 wires to the pins 1, 2, 3, 13,
14 and (6, 7, 8) to the VGA connector.
LYNX-II LCD Replacement MOD REV2.0
(see picture below)
!!! Use hot glue for the internal screws of VGA connector. Otherwise the screws may cause short circuit !!!