Issue 2 April 1996
6-13
Connectivity
To Program PBX Ports
Procedure 3:
Voice and
data
Use the following steps to program a 7400B data module that
carries voice and data. You may have to use modem pooling.
Step
Action
1
Enter the following command:
add station
2
Enter an analog station type in the Type field.
Example:
7101
3
Enter the analog port location in the Port field.
End
Step
Action
1
Enter the following command:
add station
2
Complete the following fields.
At this field …
Enter this …
Type
A digital station that supports a
data module.
Example:
7407D
Port
The digital port location
Data module
y
Data Ext
The data module extension
End
Summary of Contents for OneVision DEFINITY G3 Guide
Page 11: ...Contents xii Issue 2 April 1996 GL Glossary GL 1 IN Index IN 1...
Page 78: ...4 18 Issue 2 April 1996 UnixWare Administration To Back Up and Restore...
Page 114: ...5 36 Issue 2 April 1996 Planning Connectivity Alarm Path 5 Proxy Agent PC...
Page 124: ...6 10 Issue 2 April 1996 Connectivity Digital Connections 5 Data module or ADU 6 Proxy Agent PC...
Page 172: ...7 24 Issue 2 April 1996 Serial I O Cards To Create Port Monitor Entries...
Page 235: ...A 4 Issue 2 April 1996 PA001 Form PA001 Administration Request Form...
Page 237: ...A 6 Issue 2 April 1996 PA001 Form PA001 Administration Request Form...
Page 243: ...Issue 2 January 1996 B 5 Design Configuration Analog On Network...
Page 245: ...Issue 2 January 1996 B 7 Design Configuration Analog On Network...
Page 247: ...Issue 2 January 1996 B 9 Design Configuration Other On Network...
Page 250: ...B 12 Issue 2 January 1996 Design Configuration Customer Provided Multiplexor Data Networks...
Page 253: ...Issue 2 January 1996 B 15 Design Configuration Customer Provided Multiplexor Data Networks...
Page 259: ...Issue 2 January 1996 B 21 Design Configuration Local Connection 5000 or Less G3rV1 V2 V3...
Page 262: ...B 24 Issue 2 January 1996 Design Configuration Remote Connection G3rV1 V2 V3...