System Features
Programming Procedures
4–261
Summary: Disallowed Lists
Programmable by
System manager
Mode
All
Idle Condition
Not required
Planning Form
Form 6g, Call Restriction Assignments and Lists
Factory Setting
List #7 containing the following:
0, 10, 11, 1809, 1700, 1900, 976,
1ppp976 (p = wildcard), *
Valid Entries
1- to 11-digit number (including wildcards)
Inspect
No
Copy Option
No
Console Procedure
Tables
®
Disallow
®
Dial list no. and entry no.
®
Enter
®
Drop
®
Dial no.
®
Enter
®
Exit
PC Procedure
8
®
3
®
Type list no. and entry no.
®
0
®
A
+
P
®
Type no.
®
0
®
5
Assign Disallowed Lists to Telephones
Use this procedure to assign established Disallowed Lists to individual
telephones. Each restricted telephone can be assigned to more than one list.
Summary: Assign Disallowed Lists to
Telephones
Programmable by
System manager
Mode
All
Idle Condition
Not required
Planning Form
Form 6g, Call Restriction Assignments and Lists
Factory Setting
Not applicable
Valid Entries
0 to 7
Inspect
Yes
Copy Option
Yes
Console Procedure
Tables
®
DisallowTo
®
Dial list no.
®
Enter
®
Dial ext. no.
®
Enter
®
Exit
®
Exit
PC Procedure
8
®
4
®
Type list no.
®
0
®
Type ext. no.
®
0
®
5
®
5
Summary of Contents for MERLIN LEGEND Release 3.1
Page 372: ...Memory Card 3 236 Common Administrative Procedures...
Page 572: ...Telephones 4 200 Programming Procedures...
Page 715: ...Memory Card Programming Procedures 4 343...
Page 749: ...Feature Quick Reference 5 34 Centralized Telephone Programming...
Page 773: ...Customer Support Information B 2 System Programming...
Page 798: ...Button Diagrams E 6 System Programming...
Page 800: ...Sample Reports F 2 System Programming Continued on next page...