Installation and Operations Manual
AT&T Proprietary (Internal Use Only)
—84—
6.2.4.4 Specifications
General Specifications—V2 Sensor
Operating Temperature
32° to 120° F (0° to 49° C)
Operating Rel.
Humidity
5 to 95%, non-condensing
Operating Frequency
433.92MHz
Battery
3-Volt CR2032 Lithium Battery
6.2.5 Recessed Door/Window (RDW) Sensor
The AT&T model number
SW-ATT-RDW
is a fully supervised door/window sensor that
reports to the DLC. The detection portion of the device is imbedded into the door or
window frame, while the integral magnet is installed adjacent to the detection device.
Opening the door or window will cause the radio transmitter to send an alarm report.
Closing the door or window will cause the radio transmitter to send a restore code.
6.2.5.1 Discovering and Registering the RDW Sensor
Follow these steps to discover and register the RDW sensor:
Step
Action
1.
Place the DLC into Discovery Mode in DLD.
2.
Make the RDW sensor discoverable by inserting the battery.
3.
Confirm that the RDW sensor has been discovered in DLD.
4.
Label the RDW sensor in DLD.
6.2.5.2 Installing and Mounting the RDW Sensor
Locating the Transmitter
For Door Installation: Select the location where the RDW sensor is to be mounted. Two
locations are preferred. The transmitter can be located in the top portion of the door jam,
near the side where the door opens, or it can be located near the top of the door jam on
the side where the door opens. The integral magnet will be mounted in the door.
For Window Installation: Select the location where the RDW sensor is to be located.
Mount the transmitter in the window jam near the top of the section of the window to be
protected. The integral magnet should be mounted in the window.