Turn the Power On
1 If there is an Auxiliary Power Unit(s), plug it (them)
into the ac outlet.
2 If there is an expansion carrier(s), set that power
supply switch to the ON position.
The green power light on the Power Supply Module goes on.
3 Set the power switch on the basic carrier’s Power
Supply Module to On.
The green power light on the Power Supply Module goes on.
The red warning light on the Processor Module should go off in 30
to 45 seconds.
To Turn the Power Off
1 First turn off the power at the basic carrier.
2 Then turn the power off at the expansion carrier(s).
3 Finally, if there are Auxiliary Power Units, unplug
them from the ac outlet. Because the MERLIN II
Power Supply Modules are already OFF, the auxiliary
power cord removal sequence is not important.
Normal Operation
If the system is operating properly, you will find these
indicators:
●
The green power light on the Power Supply Module
remains on.
●
The red light on the Processor Module goes on for 30
to 45 seconds during power-up and then goes off.
●
All indicators on the Tie Line Module remain off when
that module is idle. See “Tie Line Module, Status
Indicators” on page 1-25.
If any of the conditions listed have not occurred, refer to
Section 4, “Troubleshooting.”
Installing the Control Unit 2-91
Summary of Contents for administration and
Page 40: ...FIGURE 1 9 System architecture Theory of Operation 1 37 ...
Page 175: ...Top cover Front cover FIGURE 2 27 Control unit covers Testing the System 2 107 ...
Page 211: ...FIGURE 3 I A MERLIN II System Display Console The Administrator Attendant Console 3 3 ...
Page 213: ... FIGURE 3 2 A BIS 34D Console The Administrator Attendant Console 3 5 ...
Page 331: ...General Tests 4 55 Reaming the Control Unit 4 55 Testing Outside Lines 4 56 ...