background image

Summary of Calls by Extension Number:

SUMMARY BY EXTENSION    12/12

EXT.  CALLS    DURATION  COST

0020
0021
0027

0007
0006
0008

000095
000095
000063

0012.23
0004.13
0015.61

TOT   CALLS    DURATION  COST

000021    00000253 000031.97

Summary of Calls by Account Number:

SUMMARY BY ACCOUNT      12/12

ACCT CODE  CALLS    DURATION  COST

56
123
1238
1256
5678
567789
567890
1567890
9581985
219581985

0001
0001
0001
0001
0005
0001
0002
0001
0001
0001

000001
000037
000032
000001
000039
000001
000008
000001
000001
000011

0000.50
0000.00
0003.97
0000.50
0007.12
0000.54
0000.50
0000.42
0000.69
0000.00

TOT          CALLS    DURATION  COST

0015      000132  0014.24

20

Summary of Contents for 61370

Page 1: ...AT T CIB 3067 CALL ACCOUNTING SYSTEM CAS MODEL 100 61370 845656818...

Page 2: ...Changing the Baud Rate of the CAS s Output Testing Procedures System Diagnostics Message Call Record Verification Reports Chronological Report Summary Reports by Hour by Line Number by Extension Numb...

Page 3: ...Model 100 After each incoming or outgoing call is completed a call record is printed on the chronological report Figure 2 Each call record includes the date and time of each call its duration in minu...

Page 4: ...0 00 50 11 05 00 99 00 00 03 13 00 54 1567890 219581985 5678 123 1238 5678 1256 567890 9581985 5678 5678 567890 5 6 567789 0 1 0 2 0 3 0 7 2 5 3 0 0 0 0 1 0 2 0 3 0 7 2 5 3 0 2 0 0 0 0 0 0 1 0 4 1 0 1...

Page 5: ...ore installing the CAS be sure that a SMDR Module is installed in slot 5 of your control unit Also make sure that the SMDR options have been administered according to the instructions in your administ...

Page 6: ...ons below Install wiring from the SMDR Module in the control unit to the loca tion of the CAS in the same manner that you installed it for your voice terminals Refer to the installation guide you rece...

Page 7: ...adapter Printer s RS232 connector Power supply 4 5 Figure 5 CAS Installation 15 Feet to 1 000 Feet From the Control Unit Plug the other end of the modular cord into the modular jack on the 355AF adapt...

Page 8: ...of the CAS s Output Plug the CAS s power supply into a 3 prong power outlet that is not con trolled by a wall switch The green light labeled Power goes on Insert your custom cartridge into the cartri...

Page 9: ...otherwise continue to the next section titled Testing Procedures Value Preset System Option Definition Range Value Percentage Increases the recorded 0 99 0 markup cost of outgoing calls by a specified...

Page 10: ...ox 1 Switch Box 2 Switch Box 3 Cartridge Figure 8 Positioning the CAS and Locating System Option Switch Boxes 4 5 Locate the red switch boxes above the ac power cord inside the CAS Figure 8 Follow the...

Page 11: ...o set any switches All switches on the side of the switch box contain ing the zero should be in the up position Locate the first digit of the percentage you want to set on the table below Example 25 2...

Page 12: ...B Side A Side B 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 If you want to set other system options continue following the instructions below Otherwise skip to the section titled Replacing the CAS s Cover LINE S...

Page 13: ...2 4 2 5 1 4 5 1 1 1 2 4 2 8 2 4 5 1 2 3 4 2 7 1 2 4 5 1 3 1 3 4 2 8 3 4 5 1 4 2 3 4 2 9 1 3 4 5 1 5 1 2 3 4 3 0 2 3 4 5 3 1 1 2 3 4 5 Locate the switch numbers that are next to the number of blank li...

Page 14: ...uppress records for local calls 7 Suppress records for calls without account numbers 8 2 Slide the switch number upon Side B of Switch Box 2 for the option s to be suppressed Figure 11 Example To supp...

Page 15: ...remains down on Switch Box 3 3 To change the baud rate to 600 slide switch number 6 up and switch number 7 down switch number 5 remains down on Switch Box 3 4 Replace the CAS s cover following the ins...

Page 16: ...you may have set To generate a system diagnostics message Figure 14 follow the instructions below 053084 201834 212516 609213 F0ATT0 F8ATT0 E0ATT0 E8ATT0 00 00 00 50 00 00 00 50 00 00 00 00 00 0 0 00...

Page 17: ...eceiving information from your communications system and producing call records Figure 15 follow the steps Iisted below 12 11 08 22 0020 14544466 NJ 001 00 42 01 Figure 15 Telephone Call Record 1 Plac...

Page 18: ...roduced by the CAS will contain slightly inflated cost information CHRONOLOGICAL REPORT The Chronological Report Figure 16 is a list of all incoming and outgoing call records Each call record is print...

Page 19: ...a NB New Brunswick Providence of Canada NF New Foundland Providence of Canada NS Nova Scotia Providence of Canada ON Ontario Providence of Canada OP Operator Assisted OV Overseas PQ Quebec Providence...

Page 20: ...00 000000 000000 000000 000000 000000 000000 000000 000000 0000 00 0000 00 0000 00 0000 00 0000 00 0000 00 0000 00 0000 00 0000 92 0007 48 0001 69 0005 67 0011 55 0004 66 0000 00 0000 00 0000 00 0000...

Page 21: ...031 97 Summary of Calls by Account Number SUMMARY BY ACCOUNT 12 12 ACCT CODE CALLS DURATION COST 56 123 1238 1256 5678 567789 567890 1567890 9581985 219581985 0001 0001 0001 0001 0005 0001 0002 0001 0...

Page 22: ...nected to an outlet controlled by a switch Check the connections between the CAS and its ac power outlet and between the printer and its ac power outlet Test the outlet by plugging in a lamp or radio...

Page 23: ...ceived with your printer to set its baud rate to 1200 If this is not possible refer to or The CAS is not set to the same baud rate as the section of this document titled Chang ing the Baud Rate of the...

Page 24: ...ersons other than AT T Power failures or surges fire flood accident actions of third parties and other events outside AT T s control Except as specifically made in this agreement AT T and its affiliat...

Page 25: ...TABLE Specifications Extension capacity 4 digits Dialed number capacity 10 digits Access number 1 Line capacity 49 lines 1 49 Station capacity 120 stations 0 119 Account code print capacity 9 digits T...

Page 26: ...AT T Issue 1 Copyright 1985 AT T Printed in U S A...