background image

Measurement Value 

 

The main scale indicates Oe (GER) and the secondary scale indicates Brix. 
 

Automatic Temperature Compensation 

 

The readings are corrected, based on the temperature of the prism, within the automatic temperature compensation range. 
【Caution】 

 

Measurements may fluctuate with hot or cold samples. Wait for approximately 20 seconds to press the START button. 
Measurements will stabilize once the instrument acclimates to the sample temperature. 

 

Storage and Maintenance 

 

Store the instrument in a dry place 
away from direct sunlight. Exposure to 
humidity and heat may damage the 
instrument. 

 

Clean and dry the sample stage thoroughly, 
following the “Cleaning” instructions.   
Store the unit away from direct sunlight at a 
stable temperature with as little fluctuation as 
possible.

 

   

 

Repair and Warranty 

 

The instrument is warranted for one year from the date of purchase. This warranty is void if the instrument shows evidence of the 
following. Send the included batteries as well if they are still in use. 

 

Having been disassembled by unauthorized personnel 

 

Damages to the prism and/or sample stage 

 

Water damage or having been dropped 

 

Having been misused and/or operated outside the environmental specifications 

 

Leakage from batteries other than those included with the unit 

Repair services are available for a fee after the warranty expires. 
Contact an ATAGO authorized service center for service and support. 

Please have the serial number information ready when contacting a service center. 

 

Specifications 

 

Measurement range 

Main scale : Oe (GER) 30 to 240°/ 10.0 to 40.0℃    Sample volume 

At least 0.3mL 

 

Secondary scale : Brix 0.0 to 53.0% / 10.0 to 100℃    Measurement time  Approx. 3 seconds 

Resolution 

Main scale : Oe (GER) 1° 

  Backlight 

The backlight stays on for 30 seconds after   

 

Secondary scale : Brix 0.1% 

   

any button is pressed. 

 

Temperature : 0.1℃ 

  Power supply 

Two (2) AAA alkaline batteries 

Accuracy 

Main scale : Oe (GER) 

±

1° 

  Battery life 

Approx. 11,000 measurements   

 

Secondary scale : Brix 

±

0.2% 

   

(when using alkaline batteries) 

 

Temperature : 

±

1℃ 

  International 

IP65 

Automatic temperature  Oe (GER) : 10 to 40℃ 

  Protection class 

 

compensation range 

Brix : 10 to 100℃ 

  Dimensions   

55 (W) x 31 (D) x 109 (H)mm, 

Ambient temperature 

10 to 40℃ 

  and weight 

100g (main unit only) 

range 

 

   

 

 
 
 
 
 

The product is in conformity with the requirements of the EMC Directive 2004/108/EC. 

Patent Granted in Japan, United States, Germany, China and Taiwan. 

 

 

Headquarters: The Front Tower Shiba Koen, 
23rd Floor 2-6-3 Shiba-koen, Minato-ku, 
Tokyo 105-0011, Japan 
TEL: 81-3-3431-1943   
[email protected] 
http://www.atago.net/ 

 

 

TEL: 1-425-637-2107 
[email protected] 

 

TEL: 91-22-2854-4915 / 4071-3232 
[email protected] 

 

TEL: 66-21948727-9 ,66-21171549 
[email protected] 

 

TEL: 55 16 3913-8400 
[email protected] 

 

TEL: 39 02 36557267 
[email protected] 

 

TEL: 86-20-38108256   
[email protected] 

 

TEL: 7-812-777-96-96   
[email protected] 

 

TEL: 234-707-558-1552   
[email protected] 

 

TEL: 7-727-257-08-95 
[email protected] 

2108K  Printed  in  Japan 

4596-E06 

 

Digital Hand-held  “Pocket

 Wine Refractometer 

Instruction Manual

PAL-OWE2 

Cat.No.4596 

 

Parts 

 

 

 

Contents 

 

 

Main unit ......... 1 

 

Instruction Manual (this book) ..... 1 

 

Calibration Report .. 1 

 

AAA batteries ........... 2 

AAA alkaline batteries are included. Remove the tape from the battery compartment before inserting the batteries. 

ATAGO instruments are rigorously inspected to ensure each unit meets the highest standards of quality assurance. 

 

Introduction 

 

Thank you for purchasing the instrument. Carefully read and follow all instructions. Keep this manual for future reference. 
 

Safety Instructions 

Read and follow all safety instructions before operating the instrument. Failure to comply with the following instructions may result in personal injury or 
property damage. 

 

 

Ensure safety when handling hazardous materials. Observe precautionary measures and use protective equipment, Be aware of the hazards of such 
chemicals and emergency response guidelines. 

 

ATAGO may not be held liable for any injury or damage arising in connection with handling of hazardous materials during the use of the instrument. 

 

Do not drop the instrument or subject it to strong physical shock. 

 

Do not attempt to repair, modify, or disassemble the instrument. 

 

 

Carefully read this manual to have basic knowledge of the function of each component. 

 

ATAGO is not liable for any loss and damage caused by the measurement and use of this instrument. 

 

Some acids may corrode the glass prism and/or metal sample stage, which may cause erroneous measurements. 

 

Do not use metal tools, such as a spoon, as they may scratch the prism, resulting in erroneous measurements.

 

 

Do not use water above 50℃  to rinse the instrument. 

 

Only use the specified battery type. Observe proper polarities, properly aligning the anodes and cathodes.   

 

Store the instrument away from direct sunlight/heat sources and excessive amounts of dust/debris. 

 

Do not expose the instrument to a rapid change in ambient temperature.   

 

Do not subject the instrument to strong vibration. 

 

Do not subject the instrument to extreme cold temperature. 

 

Do not place the instrument under anything heavy. 

 

Loosen the battery compartment cover for air transportation. 

 

<International Protection Classification IP65> 

 

The instrument is water-resistant, not waterproof, and should not be submerged. 

 

<Chemical Resistance of Body Case> 

 

The body case is made of resin. Do not expose it to water vapor or solvents. See the list of 

Solvents Harmful to Body Case.

 

 

Press to take measurements and 
hold down to turn off the display. 

START button 

Place and remove batteries 
from here. 

Battery compartment 

Sample stage 

Apply water and samples on the glass prism 
located in the center of the sample stage. 

ZERO button 

Press to perform zero-setting. 

Lanyard hole 

Measurement results, prism 
temperature, and remaining battery 
charge are displayed. 
The displayed value is an example. 

LCD 

 

This photo is just for instruction.

Reviews: