Ripeness 

0~100%

NFC

PAL-HIKARi Ripeness

8460-E01

Introduction

Measurement tips and precautions

Replacing the Batteries

Error Meassages

Thank you for purchasing the instrument.

Read  and  follow  all  safety  instructions 

before operating the instrument. 

Fairure  to  comply  with  the  following  instruc-

tions may result in personal injury or property 

damages.

This  instrument  measures  amount  of  light 

absorbed by shining the light to the sample then 

converts to ripeness to display.

Ripeness can be measured with no need to cut 

and squeeze the samples. 

This  product  was  developed  by  utilizing  the 

research results of the National Agriculture and 

Food Research Organization (NARO).

Place a sample, then 

press the START button.

Press the 

START button

Press the 

side button

Press against a sample, 

then press the side button.

The measurements are displayed.

LCD Auto Shut-off

The instrument will turn itself off 

after 2 minutes of inactivity. 

To manually turn it off, hold down 

the START button for more than 

3 seconds.

The temperature difference between the 

surface and the inside of the sample, and 

temperature difference between this 

instrument and the sample may affect the 

measurement values.

Especially when measuring refrigerated 

samples, be sure to let the samples 

acclimate to the ambient temperature.

The instrument may not measure correctly 

when there is water droplets, dust or 

scar, and bruising soft spots.

Measure an area larger than 70mm in 

diameter with no dents. 

Be sure to avoid any spacing between 

the sample and the outer cushion to 

avoid the external light interference. If the 

cushion is deteriorated, please replace it 

with a brand new cushion. (Refer to “How 

to change the cushion”)

Example for measurement value: Take 

few measurements from the same 

sample, then compute and use the 

average.

Acclimate the sample and this 

instrument to ambient temperature.

● 

Clean the surface of the samples. 

   Do not measure the spoiled spots.

● Place the sample stage to the sample.

● 

Ripeness

 varies depending on the 

measured area.

When there is an operation error or malfunction, the 

below error message will show with alarm sound or alarm 

vibration can for warning.

The battery is low.

Measurement was 

taken for samples with 

Brix lower than the 

measurement range.

Measurement 

was taken when 

the unit’s 

temperature was 

5˚C or lower.

Measured when 

the main unit’s 

temperature is 

exceeding 45

.

Measurement 

was taken when 

t h e   s a m p l e ’s  

temperature was 

5˚C or lower.
Measured when 

t h e   s a m p l e ’ s  

temperature is 

exceeding 45

.

Measurement was 

taken for samples with 

Brix highter than the 

measurement range.

The instrument is 

faulty. Replace the 

batteries. Contact 

ATAGO if this error persists.

Main unit’s temperature 

error will preferentially 

display when the main unit’s 

and sample’s temperatures 

are both out of range.

When it is outside of temperature 

compensation range.

Digital Hand-held “Pocket” IR Ripeness Meter

or

1. Insert a coin in the groove on the battery

 

 compartment cover. Turn the coin 

 

 counterclockwise to remove the cover.

2. Insert two batteries

3. Align the cover and push it down.

4. Close the battery compartment cover by 

  

pushing the cover in with a coin in the groove 

  

and turning it clockwise until it stops.

Observe the correct polarity.

Groove

When the 

cover is 

open

When the 

cover is 

closed

About battery indicator

When the battery icon indicates the low power 

level , replace both batteries with a brand new 

set of AAA alkaline batteries (1.5V).

*

Check the expiration dates on batteries before 

purchase.

Touch the sample and do not move.

Beep

Beep

Beep

Note

Measurement was 

taken while the sample 

stage was not in  

contact with sample.

When correct measurements are 

not achievable due to interference 

from external light.

There is a temperature 

difference between the 

sample and the main 

unit.

Parts

Contents

Main unit

・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・

1

Instruction Manual(this book)

・・・・・・・・・・・・・・・・・・・・・

1

Inspection Report

・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・

1

・C

ushion RS (for replacement)

・・・・・・・・・・・・・・・・・・・・

3

AAA alkaline batteries

・・・・・・・・・・・・・・・・・・・・・・・・・・・・・

2

AAA alkaline batteries are included. 

Remove the tape from the battery compartment before 

closing the battery compartment cover. (Refer 

to “Replacing the Batteries”)

Silicon cushion R

Light emitting part

Radiation 

temperature

sensor

Cushion RS

Receiver
START button

Battery compartment

Side button

Sample stage

LCD

Menu button

Lanyard hole

Access now

In just-a-minute

1. It requires 

only 1 minute!

 Simply by answering questions, warranty period is extended from 1 year to 2 years.

2. ATAGO Logger NFC can also be downloaded at the same time.

(The registration page can be accessed from ATAGO website.)

From 

1

 year to 

2

 years        

Free Extended Warranty

Measurement

Cat.No.8460

PAL-HIKARi Ripeness

Instruction Manual

Full

When the history of measured data reaches 

100. 

Turn OFF the NFC Function or Delete 

Data History. 

71

76

72

73

71+72+76

3

83

83

83

83

83