background image

Automatic Temperature Compensation

Automatic Temperature Compensation

Automatic Temperature Compensation

Automatic Temperature Compensation    

The readings are corrected, based on the temperature of the prism, within the automatic temperature compensation range. 

【Caution】 

 

Measurements may fluctuate with hot or cold samples. Wait for approximately 20 seconds to press the START button. 

Measurements will stabilize once the instrument acclimates to the sample temperature. 

 

Storage and Maintenance

Storage and Maintenance

Storage and Maintenance

Storage and Maintenance    

Store the instrument in 

a dry place away from 

direct sunlight. 

Exposure to humidity 

and heat may damage 

the instrument. 

 

Do not use organic 

solvents (paint 

thinner, benzene, 

gasoline, etc.) on the 

plastic body case. 

 

Clean and dry the sample 

stage thoroughly, following 

the 

Cleaning

 instructions.   

Store the unit away from 

direct sunlight at a stable 

temperature with as little 

fluctuation as possible.

 

 

Repair and Warranty

Repair and Warranty

Repair and Warranty

Repair and Warranty    

The instrument is warranted for one year from the date of purchase. This warranty is void if the instrument shows evidence of the 

following. Send the included batteries as well if they are still in use. 

Having been disassembled by unauthorized personnel 

Damages to the prism and/or sample stage 

Water damage or having been dropped 

Having been misused and/or operated outside the environmental specifications 

Leakage from batteries other than those included with the unit 

Repair services are available for a fee after the warranty expires. 

Contact an ATAGO authorized service center for service and support. 

Please have the serial number information ready when contacting a service center. 

 

Specifications

Specifications

Specifications

Specifications    

Measurement range 

Glycerin 60.0 to 99.0% (g/100g) 

  Measurement time  Approx. 3 seconds 

 

10.0 to 40.0℃ 

  Power supply 

Two (2) AAA alkaline batteries 

Resolution 

0.2% / 0.1℃ 

  Battery life 

Approx. 11,000 measurements   

Accuracy 

±

0.4% / 

±

1℃ 

   

(when using alkaline batteries) 

Automatic temperature 

compensation range 

10 to 40℃ 

  International   

Protection class 

IP65 

Ambient temperature range  10 to 40℃ 

  Dimensions   

55 (W) x 31 (D) x 109 (H)mm,   

Sample volume 

At least 0.3ml 

  and weight 

100g (main unit only) 

 

 

 

 

 

 

 

 

 

 

 

The product is in conformity with the requirements of the EMC Directive 2004/108/EC. 

Patent Granted in Japan, United States, Germany, China and Taiwan. 

 

 

Headquarters: The Front Tower Shiba Koen, 

23rd Floor 2-6-3 Shiba-koen, Minato-ku, 

Tokyo 105-0011, Japan 

TEL: 81-3-3431-1943    [email protected] 

http://www.atago.net/ 

 

TEL: 1-425-637-2107 

[email protected] 

 

TEL: 91-22-2854-4915 / 4071-3232 

[email protected] 

 

TEL: 662-982-8718-9 

[email protected] 

 

TEL: 55 16 3916-6000 

[email protected] 

 

TEL: 39 02 36557267 

[email protected] 

 

TEL: 86-20-38108256 

[email protected] 

 

TEL: 7-812-339-20-02 

[email protected] 

1409K Printed in Japan 

Pocket

Pocket

Pocket

Pocket

 Glycerin (High concentration) refractometer

 Glycerin (High concentration) refractometer

 Glycerin (High concentration) refractometer

 Glycerin (High concentration) refractometer    

PAL

PAL

PAL

PAL----24S

24S

24S

24S    

Cat.No.4424 

4424-E04 

 

Instruction Manua

Instruction Manua

Instruction Manua

Instruction Manuallll

 

 

Parts

Parts

Parts

Parts    

 

 

Contents

Contents

Contents

Contents    

Main unit.........1 

Instruction Manual (this book) .....1 

Calibration Report .. 1 

AAA batteries ...........2 

AAA alkaline batteries are included. Remove the white strip from the battery compartment before inserting the batteries. 

ATAGO instruments are rigorously inspected to ensure each unit meets the highest standards of quality assurance. 

 

Introduction

Introduction

Introduction

Introduction    

Thank you for purchasing 

the instrument

. Carefully read and follow all instructions. Keep this manual for future reference. 

 

Safety 

Safety 

Safety 

Safety Instructions

Instructions

Instructions

Instructions    

Read and follow all safety instructions before operating the instrument. Failure to comply with the following instructions may result in personal injury or 

property damage. 

 

 

Ensure safety when handling hazardous materials. Observe precautionary measures and use protective equipment, Be aware of the hazards of such 

chemicals and emergency response guidelines. 

 

ATAGO may not be held liable for any injury or damage arising in connection with handling of hazardous materials during the use of the instrument. 

 

Do not drop the instrument or subject it to strong physical shock. 

 

Do not attempt to repair, modify, or disassemble the instrument. 

 

 

Carefully read this manual to have basic knowledge of the function of each component. 

 

ATAGO is not liable for any loss and damage caused by the measurement and use of this instrument. 

 

Some acids may corrode the glass prism and/or metal sample stage, which may cause erroneous measurements. 

 

Do not use metal tools, such as a spoon, as they may scratch the prism, resulting in erroneous measurements.     

 

Do not use water above 30℃  to rinse the instrument. 

 

Only use the specified battery type. Observe proper polarities, properly aligning the anodes and cathodes.   

 

Store the instrument away from direct sunlight/heat sources and excessive amounts of dust/debris. 

 

Do not expose the instrument to a rapid change in ambient temperature.   

 

Do not subject the instrument to strong vibration. 

 

Do not subject the instrument to extreme cold temperature. 

 

Do not place the instrument under anything heavy. 

 

Loosen the battery compartment cover for air transportation. 

 

<International Protection Classification IP65

International Protection Classification IP65

International Protection Classification IP65

International Protection Classification IP65>

>    

 

The instrument is water-resistant, not waterproof, and should not be submerged. 

 

<Chemical Resistance of Body Case>

<Chemical Resistance of Body Case>

<Chemical Resistance of Body Case>

<Chemical Resistance of Body Case>    

 

The body case is made of ABS resin. Do not expose it to water vapor or solvents. See the list of 

Solvents Harmful to Body Case.

 

 

Press to take measurements and 

hold down to turn off the display. 

START button 

Place and remove batteries 

from here. 

Battery compartment 

Sample stage 

Apply water and samples on the glass prism 

located in the center of the sample stage. 

ZERO button 

Press to perform zero-setting. 

Lanyard hole 

Measurement results, prism 

temperature, and remaining battery 

charge are displayed. 

The displayed value is an example. 

LCD 

(ES) Equipements Scientifiques SA - Département 

Bio-tests & Industries 

- 127 rue de Buzenval BP 26 - 92380 Garches

Tél. 01 47 95 99 

90

 - Fax. 01 47 01 16 22 - e-mail: 

bio

@es-france.com - Site Web: www.es-france.com

Summary of Contents for PAL-24S

Page 1: ...caused by the measurement and use of this instrument Some acids may corrode the glass prism and or metal sample stage which may cause erroneous measurements Do not use metal tools such as a spoon as they may scratch the prism resulting in erroneous measurements Do not use water above 30 to rinse the instrument Only use the specified battery type Observe proper polarities properly aligning the anod...

Page 2: ...ture approximately 20 seconds to press the START button Alternatively press the START button multiple times until measurements become stable Do not splash water above 30 The plastic may warp which may compromise the water resistance When measuring hot samples place only the necessary amount and do not let it overflow from the sample stage well When hot water is necessary to clean off hardened samp...

Page 3: ... 1 1 Insert a coin in the groove on the battery compartment cover Turn the coin counterclockwise to remove the cover 2 2 2 2 Insert batteries observing the correct polarity 3 3 3 3 Align the cover and push it down 4 4 4 4 Close the battery compartment cover by pushing the cover in with a coin in the groove and turning it clockwise until it stops Solvents Harmful to Body Case Solvents Harmful to Bo...

Page 4: ...ed with the unit Repair services are available for a fee after the warranty expires Contact an ATAGO authorized service center for service and support Please have the serial number information ready when contacting a service center Specifications Specifications Specifications Specifications Measurement range Glycerin 60 0 to 99 0 g 100g Measurement time Approx 3 seconds 10 0 to 40 0 Power supply T...

Reviews: