GB 15
assembly
(continued)
fitting the upper telescopic pipe
Fix the plugs and threaded ends in the ceiling. Screw two
nuts onto the threaded ends in the opposite direction. Screw
the threaded ends into the plugs in the ceiling, leaving
20 mm projecting.
Remove the nuts.
Place the upper telescopic pipe over the threaded ends. Put
the washers on and tighten the nuts.
mounting socket
Slide the mounting socket into the upper pipe until the
bottom edge is at the correct distance from the worktop (see
illustration).
Dimension A = 340 mm
Fasten the mounting socket using the four bolts (M5 x 12),
washers and nuts M5.
20
A
650
GB 14
assembly
(continued)
fitting island models
The most important dimensions are given above. You can
adjust the height of the telescopic pipe. Bear in mind the
permitted tolerances.
It is advisable to suspend the hood with the help of an
assembly lift. If there is no lift present, it is advisable to carry
out the mounting with more than one person.
Position the discharge and the electrical connection in such
a way that it will be easy to hook up the hood.
marking
Mark the holes to be drilled on the ceiling by means of the
stencil.
Drill the holes (4 x 10 mm).
¿150/125
520
700
755
1000
250
240
800-1025
min. 650
130
EG3/4/8X
building-in dimensions island hood