background image

2-lines display

Scientific Calculator

with

fractional, statistical,

formula memory,

equation solving

functions

Please read before using.

O

w

n

e

r'

M

a

n

u

a

l

Safety Precautions

Be  sure  to  read  the  following  safety  precautions  before 
using  this  calculator.  Keep  this  manual  handy  for  later 
reference.

Batteries

•  After  removing  the  batteries  from  the  calculator,  put 

them in a safe place where there is no danger of them 
getting into the hands of small children and accidently 
swallowed.

• Keep batteries out of the reach of children. If accidentally 

swallowed, consult with a physician immediately.

•  Never  charge  batteries,  try  to  take  batteries  apart,  or 

allow  batteries  to  become  shorted.  Never  expose 
batteries  to  direct  heat  or  dispose  of  them  by 
incineration.

• Misuse of batteries can cause them to leak acid that can 

cause  damage  to  nearby  items  and  creates  the 
possibility of fire and personal injury.

•  Always  make  sure  that  a  battery's  positive  (+)  and 

negative  (–)  sides  are  facing  correctly  when  you  load  it 
into the calculator.

•  Remove  the  batteries  if  you  do  not  plan  to  use  the 

calculator for a long time.

• Use only the type of batteries specified for this calculator 

in this manual.

Disposing of the Calculator

•  Never  dispose  of  the  calculator  by  burning  it.  Doing  so 

can  cause  certain  components  to  suddenly  burst, 
creating the danger of fire and personal injury.

•  The  displays  and  illustrations  (such  as  key  markings) 

shown  in  this  Owner's  Manual  are  for  illustrative 
purposes only, and may differ somewhat from the actual 
items they represent.

•  The  contents  of  this  manual  are  subject  to  change 

without notice.

Handling Precautions

• Be sure to press the "ON" key before using the calculator 

for the first time.

•  Even  if  the  calculator  is  operating  normally,  replace  the 

battery at least once every three years. Dead battery can 
leak,  causing  damage  to  and  malfunction  of  the 
calculator. Never leave the dead battery in the calculator.

• The battery that comes with this unit discharges slightly 

during  shipment  and  storage.  Because  ofthis,  it  may 
require  replacement  sooner  than  the  normal  expected 
battery life.

•  Low  battery  power  can  cause  memory  contents  to  

become  corrupted  or  lost  completely.  Always  keep 
written records of all important data.

• Avoid use and storage in areas subjected to temperature 

extremes. Very low temperatures can cause slow display 
response,total  failure  of  the  display,  and  shortening  of 
battery  life.Also  avoid  leaving  the  calculator  in  direct 
sunlight, neara window, near a heater or anywhere else it 
might become exposed to very high temperatures. Heat 
can  cause  discoloration  or  deformation  of  the 
calculator's case, anddamage to internal circuitry.

•  Avoid  use  and  storage  in  areas  subjected  to  large 

amounts of humidity and dust. Take care never to leave 
the  calculator  where  it  might  besplashed  by  water  or 
exposed  to  large  amounts  of  humidity  or  dust.  Such 
elements can damage internal circuitry.

•  Never  drop  the  calculator  or  otherwise  subject  it  to 

strong impact.

•  Never  twist  or  bend  the  calculator.  Avoid  carrying  the 

calculator  in  the  pocket  of  your  trou-sers  or  other 
tight-fitting  clothing  where  it  might  be  subjected  to 
twisting or bending.

• Never try to take the calculator apart.
•  Never  press  the  keys  of  the  calculator  with  a  ball-point 

pen or other pointed object.

• Use a soft, dry cloth to clean the exterior of the unit. If the 

calculator  becomes  very  dirty,  wipe  it  off  with  acloth 
moistened in a weak solution of water and a mildneutral 
household  detergent.  Wring  out  all  excess  moisture 
before wiping the calculator. Never use thinner, benzine 
or other volatile agents to clean the calculator. Doing so 
can remove printed markings and damage the case.

Two-lines Display

You can simultaneously check the calculation formula and 
its  answer. The  first  line  displays  the  calculation  formula. 
The second line displays the answer.

Keys Layout

Before Starting Calculations

Operation Modes
When  using  this  calculator,  it  is  necessary  to  select  the 
proper  mode  to  meet  your  requirements.    This  can  be 
done  by  pressing  [MODE]  to  view  the  main  menu  and 
select the appropriate mode by moving the cursor to the 
right or the left.

Press  [MODE]  once  to  read  the  first  page  of  the  main 
menu.

Press  [

]  to select the mode. 

As the icons [

] or [

] appear,  one can press  [

]  or  [

]  correspondingly to view the hidden menu.

 

After locating the desired mode,  press  [=]  to confirm and 
leave the main menu.

Or  if  you  want  to  define  the  "degree"  or  "radian"  or 
"gradient",    you  can  press    [MODE]  again  during  the 
display of "mode-selection" menu mentioned above.

Press  [MODE]  again.  (This  sub-menu  will  be  skipped  in 
Base-N mode.)

Select  the  angular  unit  by  pressing    [

]    or    [

]    then 

followed by  [ = ].

Or  if  you  want  to  define  the  answer  display  format,    you 
can  proceed  to  the  following  page  by  pressing    [MODE] 
further. (This sub-menu will be skipped in Base-N mode.)

Press "MODE" once more to leave the menu.

Calculation Modes
"COMP"
 mode : - general calculations, including function 
calculations can be    executed.
"CMPLX" mode:- calculations including complex numbers 
can be executed.
"SD"  mode:-  standard  deviation  calculation  can  be 
executed. "SD" symbol appears in display.
"REG"  mode:-  regression  calculations  can  be  performed. 
"LR" symbol appears in display.
"BASE-N"  mode:-  binary,  octal,  decimal,  hexadecimal 
conversion and calculations,  as well as logical operations 
can be carried out.

Note:- 
•  The  five  calculation  modes  listed  above  are  totally 

independent, and cannot be used together.

• The calculation mode last selected is retained in memory 

when the power is switched OFF.

Angular Measurement Modes 
"DEG"  mode:-    specify  measurement  in  "degrees".  "D" 
symbol appears in display window.
"RAD"  mode:-  specify  measurement  in  "radians".  "R" 
symbol appears in display window.
"GRA"  mode:-  specify  measurement  in  "grads".  "G" 
symbol appears in display window.

With  the  exception  of  the  BASE-N  mode,  these  three 
angular  measurement  modes    can  be  used  in 
combination with the manual calculation modes.

 Display Modes
"FIX"
  mode:-  specify  number  of  decimal  places.  "FIX" 
symbol appears in display window.
"SCI"  mode:-  specify  number  of  significant  digits.  "SCI" 
symbol appears in display window.
"NORM" mode:- cancels "Fix" and "Sci" specifications.  This 
operation also changes the range of the exponent display.  
When the results exceed the following limits, exponent is 
to be displayed.

 Norm 1 :-    10

–2

 > |x|, or |x| 

 10

10

 Norm 2 :-    10

–9

 > |x|, or |x| 

 10

10

In combination with "FIX", "SCI" or "NORM" mode,  you can 
cause the exponent display for the number being 

displayed  to  change  in  multiples  of  3  by  pressing    the 
[ENG] key  .

• With the exception of the BASE-N mode, "FIX", "SCI" and 

"NORM"  modes  can  be  used  in  combination  with  the 
manual calculations.

•  Engineering  display  format  is  not  available  in  "CMPLX" 

mode.

•  The  display  mode  last  selected  is  retained  in  memory 

when the power is switched OFF.

Calculation Priority Sequence
This  calculator  employs  true  algebraic  logic  to  calculate 
the parts of a formula in the following order :-
1.  Coordinate  transformation  /  integration,    Pol(x,  y),Rec(r, 

), 

dx

2. Type A functions :-

These functions are those in which the value is entered 
and  than  the  function  key  is  pressed,  such  as  x

2

,  x

–1

,  x!, 

º''',  Engineering symbols.

3. Power / root,  x

y

x

4. Fractions,  a

b

/

c

5. Abbreviated multiplication format in front of 

π

, memory 

or parenthesis, such as 2

π

, 5A, 

π

6. R, etc.

6. Type B functions :-

These  functions  are  those  in  which  the  function  key  is 
pressed and then the value is entered such as 

3

, log, 

ln, e

x

, 10

x

, sin, cos, tan, sin

–1

, cos

–1

, tan

–1

, sinh, cosh, tanh, 

sinh

–1

,  cosh

–1

,  tanh

–1

,  Int,  Frac,  Abs,  (–),  (following  in 

BASE-N mode only) d, H, b, o, Neg, Not.

7.  Abbreviated  multiplication  format  in  front  of  Type  B 

functions, such as, 2

3, A log2, etc.

8. Permutation, combination,  nPr,  nCr
9. 

10. 

11. and ( in BASE-N mode only )
12. or, xor, xnor ( in BASE-N mode only )

• When functions with the same priority are used in series, 

execution is performed from right to left for :-  e

x

ln

120 

 e

x

{ln(

120)}.  Otherwise, execution is from left to right.

• Operations enclosed in parentheses are performed first.

Number of Stacks
There  is  a  memory  area  known  as  a  "stack"  for  the 
temporary  storage  of  low  priority  numeric  values  and 
commands ( functions, etc. ). The numeric value stack has 

nine levels,  while the command stack has 24.  If a complex 
formula  is  employed  that  exceeds  the  stack  space 
available, a stack error (Stk ERROR) message will appear on 
the display.

Calculations  are  performed  in  the  order  of  the  highest 
calculation priority first.  Once a calculation is executed, it 
is cleared from the stack.

Number of Input/output Digits and Calculation Digits
The  allowable  input/output  range  (number  of  digits)  of 
this  unit  is  10  digits  for  a  mantissa  and  2  digits  for  the 
exponent.  Calculations, however, are performed internally 
with a range of 12 digits for a mantissa and 2 digits for an 
exponent.

Example:  3 

 10

5

 

 7 =

3[EXP]5[

÷

]7[=]

3[EXP]5[

÷

]7[

]42857[=] 

Overflow and Errors
If  the  operational  range  of  the  unit  is  exceeded,  or 
incorrect  inputs  are  made,  an  error  message  will  appear 
on  the  display  and  subsequent  operation  will  be 
impossible.  This is carried out by the error check function.  
The following operations will result in errors :-

1. The answer, whether intermediate or final, or any value 

in memory exceeds the value of 

±

9.999999999 

 10

99

.

2.  An  attempt  is  made  to  perform  function  calculations 

that exceed the input range.

3.  Improper  operation  during  statistical  calculations,  e.g., 

attempting to obtain x or x

n without data input.

4.  The  capacity  of  the  numeric  value  stack  or  the 

command stack is exceeded.

5.  Input errors are made,  e.g.  5  

 

  3 = .

When  error  message  appears,  most  keys  will  become 
inoperative.    In  this  case,  press  the  [AC]  key  to  return  to 
normal operation.  You can also press the  [

]  or  [

]  key 

to cause the cursor to show the position of the error.

The  following  error  messages  will  be  displayed  for  the 
operations listed above:-

case (1) to case (3) 

Ma ERROR

case (4) 

 

Stk ERROR

case (5) 

 

Syn ERROR

Besides pressing [AC] when an error occurs, you can also 
press [ON] key to clear the error.

Number of Input Characters
This  calculator  features  a  79-step  area  for  calculation 
execution.  One function comprises one step.  Each press 
of numeric or  

  , 

  ,  

  and  

 keys comprise one step.  

Though such operations as [SHIFT] [x!]  (x

–1

  key) require 

two  key  operations,  they  actually  comprise  only  one 
function, and, therefore, only one step.  These steps can be 
confirmed using the cursor.  With each press of the  [

] or 

[

key, the cursor is moved one step.

Input characters are limited to 79 steps.  Usually, the cursor 
is represented by a blinking " _ ".  

When numeric values or calculation commands are input, 
they  appear  on  the  display  from  the  left.    Calculation 
results, however, are displayed from the right.

Corrections
To make corrections in a formula that is being input, use 
the  [

and [

] keys to move to the position of the error 

and press the correct keys.
Example: To change an input of 122 to 123 :-
[1] [2] [2]

[

]

[3]

Example:  To change an input of cos60 to sin60  :-
[cos]60

[

][

][

]

[sin]

If  after  making  corrections,  input  of  the  formula  is 
complete, the answer can be obtained by pressing  [ = ].  If, 
however, more is to be added to the formula, advance the 
cursor  using  the    [

]    key  to  the  end  of  the  formula  for 

input.

If  an  unnecessary  character  has  been  included  in  a 
formula,  use  the    [

]  and  [

]    keys  to  move  to  the 

position of the error and press the DEL key.  Each press of 
DEL will delete one command ( one step ).
Example:  To correct an input of 369 

 

 2 to 369 

 2 :-

[3] [6] [9] [

] [

] [2]

[

][

][DEL]

If  a  character  has  been  omitted  from  a  formula,  use  the      

 

and 

 

"  key to move to the position where the 

character  should  have  been  input,  and  press  [SHIFT] 
followed  by  [INS]  key.    Each  press  of  [SHIFT]  [INS]  will 
create a space for input of one command.

Example:  To correct an input of 2.36

2

 to sin 2.36

2

 :-

2[•]36[x

2

]

[

][

][

][

][

]

[SHIFT][INS]

[sin]

When [SHIFT] [INS] are pressed, the space that is opened 
is displayed as "     ". The function or value assigned to the 
next key you press will be inserted in the    .  To exit from 
the  insertion  mode,  move  the  cursors,  or  press  [SHIFT] 
[INS]
 , or press [=].

Even  after  the  [=]  key  has  been  pressed  to  calculate  a 
result,  it  is  possible  to  use  this  procedure  for  correction.  
Press the [

] key to move the cursor to the place where 

the correction is to be made.

Arithmetic Operations & Parenthesis Calculations 
•  Arithmetic  operations  are  performed  by  pressing  the 

keys in the same order as noted in the formula.

• For negative values, press [(-)] before entering the value
• For mixed basic arithmetic operations, multiplication and 

division are given priority over addition and subtraction

• Assuming that display mode Norm is selected.
 

Percentage Calculations
Percentage cannot be executed in Base-N mode or CMPLX 
mode.

Specifying the Format of Calculation Results
You  can  change  the  precision  of  calculation  results  by 
specifying the number of decimal places or the number of 
significant digits.  You can also shift the decimal place of a 
displayed  value  three  places  to  the  left  or  right  for 
one-touch conversions of metric weights and measures.

Upon  power  up  reset,  the  display  format  is  defaulted  at 
"Norm1".  Each  time  you  can  press  [MODE]  to  enter  the 
menu  and  select  the  desired  format  in  the  sub-menu 
"FIX/SCI/NORM".    When  you  choose  "Norm",    you  can 
further  select  between    "Norm  1"  or  "Norm  2"  in  the 
following window.

Key  in  either  1  or  2  to  specify  "Norm  1"  or  "Norm  2" 
respectively. 

Norm 1 :- all values less than 10

–2

 or greater than 10

9

 are 

automatically expressed as exponents.
Norm 2 :- all values less than 10

–9

 or greater than 10

9

 are 

automatically expressed as exponents.

Note: You cannot specify the display format (Fix, Sci) while 
the calculator is in Base-N mode.

Specifying the Number of Decimal Places
The  calculator  always  performs  calculations  using  a 
10-digit  mantissa  and  2-digit  exponent,  and  results  are 
stored  in  memory  as  a  12-digit  mantissa  and  2-digit 
exponent  no  matter  how  many  decimal  places  you 
specify.    Intermediate  results  and  final  results  are  then 
automatically  rounded  off  to  the  number  of  decimal 
places you have specified.

It should be noted that displayed results are rounded 
to the specified number of decimal places, but stored 
results are normally not rounded.

To specify the number of decimal places ( FIX ), select [FIX] 
in the sub-menu "FIX/SCI/NORM" and then you are asked 
to enter a value indicating the number of places (0~9) as 
below.
 

At this time, you should be able to see "FIX" on the display.  
The  number  of  decimal  places  specified  will  remain  in 
effect  until  Norm1  or  Norm2  is  specified  as  described 
above or significant digits are specified by selecting "SCI" 
in the sub-menu "FIX/SCI/NORM".

Rounding the Intermediate Result
As  the  number  of  decimal  places  is  specified,  the 
intermediate  result  will  be  automatically  rounded  to  the 
specified  decimal  places.    However,  the  stored 
intermediate result is not rounded.  In order to match the 
displayed  value  and  the  stored  value,  [SHIFT]  [RND]  can 
be input.

You can compare the final result obtained in the previous 
example with the final result of the following example.

Specifying the Number of Significant Digits
This  specification  is  used  to  automatically  round 
intermediate  results  and  final  results  to  the  number  of 
digits you have specified.

As  with  the  number  of  decimal  places,  displayed  results 
are rounded to the specified number of digits, but stored 
results are normally not rounded. 

To  specify  the  number  of  significant  digits  (Sci.),  select 
[SCI]  in  the  sub-menu  "FIX/SCI/NORM"  and  then  you  are 
asked to enter a value indicating the number of significant 
digits (0~9) as below.
 

Note :  "0" indicating 10 significant digits.
Meanwhile,  the "SCI" indicator will appear on the display. 

Shifting the Decimal Place
You  can  use  the  key  [ENG]  to  shift  the  decimal  point  of 
the displayed value three places to the left or right.  Each 
3-place  shift  to  the  left  is  the  same  as  dividing  the  value 
by  1000,  and  each  shift  to  the  right  is  the  same  as 
multiplying  by  1000.    This  means  that  this  function  is 
useful  when  converting  metric  weights  and  measures  to 
other metric units.

Memory
This  calculator  contains  9  standard  memories.   There  are 
two  basic  types  of  memories,  i.e.,  "variable"  memories, 
which are accessed by using the [STO] and [RCL]  keys in 

combination with the alphabets A, B, C, D, E, F, M, X and Y.  
The  "independent"  memories,  which  are  accessed  by 
using the [M+] , [Shift] [M–] and [RCL] and [M] keys. The 
variable  memory  and  independent  memory  utilize  the 
same memory area.  
Contents of both the variable and independent memories 
are protected even when the power is turned OFF.

Variable memories
Up  to  9  values  can  be  retained  in  memory  at  the  same 
time, and can be recalled when desired.

Example:   Input 123 into memory "A" :-
[AC] [1] [2] [3]

[STO] [A]

[AC]

[RCL] [A]

When  formulas  are  input,  the  result  of  the  formula's 
calculation is retained in memory.

Example:   Input the result of 123

456 into memory "B" :-

[AC] [1] [2] [3] [

] [4] [5] [6]

[STO] [B]

[AC]

[RCL] [B]

If  a  variable  expression  is  entered,  the  expression  is  first 
calculated  according  to  the  values  stored  in  the  variable 
memories used in the expression.  The result is then stored 
in the variable memory specified for the result.

Example:   Input the results of A

B into memory "C" :-

[AC] [ALPHA] [A] [

] [ALPHA] [B]

[STO] [C]

[AC]

[RCL] [C]

Syn  ERROR  is  generated  when  an  attempt  is  made  to 
input  a  substitution  formula  (such  as  C  =  A

B)  or 

multistatements  (such  as  A

B  :  C

D),  and  the  existing 

memory contents are retained.
 
When input is made in a format such as "A=log 2", where 
the  variable  is  equal  to  the  formula,  the  results  of  the 
calculation are input into the specified memory.

Example:  Executing "A=log2" :-
[AC] [ALPHA] [A] [ALPHA] [=]
[log] [2]

[=]

[AC]

[RCL] [A]

Deleting memories
To  delete  all  contents  of  variable  memories,  press  [Shift] 
followed by [Mcl] [=].

Independent Memory
Addition and subtraction (to and from sum) results can be 
stored directly in memory.  Results can also be totalized in 
memory,  making  it  easy  to  calculate  sums. The  icon  "M" 
will be lighted as long as M is not empty.

Example:  Input 123 to independent memory.

[AC] [1] [2] [3]

[M+]

Recall memory data
[AC]

[RCL] [M]

Add 25, subtract 12
25 [M+] 12 [SHIFT] [M–]

Recall memory data
[AC]

[RCL] [M]

To clear memory contents, press  [0] [STO] [M].
Addition/subtraction  to  or  from  sum  in  memory  cannot 
be  carried  out  with  [M+],  [Shift]  [M–]  keys  in  SD  mode 
and LR mode.

Difference between [STO][M] and [M+], [Shift][M–] :-
Both  [STO]  [M]  and  [M+],  [Shift]  [M–]  can  be  used  to 
input  results  into  memory,  however  when  the  [STO]  [M] 
operation is used,  previous memory contents are cleared.  
When either [M+] or [Shift] [M–] is used, value is added or 
subtracted to or from present sum in memory.

Example:  Input  456  into  memory  "M"  using  [STO]  [M] 
procedure. Memory already contains value of 123.
[AC] [1] [2] [3] [STO] [M]

[AC] [4] [5] [6] [STO] [M]

[AC]

[RCL] [M]

Example: Input 456 into memory "M" using M+.  Memory 
already contains value of 123.
[AC] [1] [2] [3] [STO] [M]

[AC] [4] [5] [6] [M+]

[AC]

[RCL] [M]

Special Functions

Answer Function

This unit has an answer function that stores the result of 
the  most  recent  calculation.  Once  a  numeric  value  or 
numeric  expression  is  entered  and  [=]  is  pressed,  the 
result is stored by this function.
To recall the stored value, press the [Ans] key.  When [Ans] 
is pressed, "Ans" will appear on the display, and the value 
can be used in subsequent calculations.

Example:  123

456 = 579

                     789

579 = 210

[AC][1][2][3][

][4][5][6][=]

[7][8][9][

][Ans]

[=]

Numeric values with 12 digits for a mantissa and 2 digits 
for an exponent can be stored in the "Ans" memory.  The 
"Ans" memory is not erased even if the power of the unit 
is turned OFF.  Each time [=] , [Shift] [%] , [M+] , [Shift] [M–] , 
and [STO] 

 (

 = A ~ F, M, X, Y ) is pressed, the value in the 

Ans memory is replaced with the new value produced by 
the  calculation  execution.    When  execution  of  a 
calculation results in an error, however, the "Ans" memory 
retains its current value.  

Note:-  Contents of "Ans" memory are not altered when 
RCL 

  (

  =  A~F,  M,  X,  Y)  is  used  to  recall  contents  of 

variable memory.  Also, contents of "Ans" memory are not 
altered when variables are input when the variable input 
prompt is displayed.

Omitting the multiplication sign (

)

When inputting a formula as it is written, from left to right, 
it  is  possible  to  omit  the  multiplication  sign  (

)  in  the 

following cases :-

• Before the following functions :-

sin,  cos,  tan,  sin

–1

,  cos

–1

,  tan

–1

,  sinh,  cosh,  tanh,  sinh

–1

cosh

–1

, tanh

–1

, log, ln, 10

x

, e

x

3

, Pol(x,y), Rec(r, 

)

example:  2sin30, 10log1.2, 2

3, 2Pol(5, 12), etc.

• Before fixed numbers, variales and memories :-

example:  2

π

, 2AB, 3Ans, etc.

• Before parentheses :-

example:  3(5

6), (A

1)(B

1), etc.

Continuous Calculation Function
Even  if  calculations  are  concluded  with  the  [=]  key,  the 
result  obtained  can  be  used  for  further  calculations.    In 
this case, calculations are performed with 10 digits for the 
mantissa which is displayed.
Example:    To  calculate 

3.14  continuing  after  3

4=12 

[AC] [3] [

] [4] [=]

(continuing) [

] [3] [•] [1] [4]

[=]

Example:  To calculate 1

3

3 =

[AC] [1] [

] [3] [

] [3] [=]

[1] [

] [3] [=]

(continuing) [

] [3] [=]

This  function  can  be  used  with Type  A  functions  (  x

2

,  x

–1

x!), 

, x

y,

 

x

 and º' ". 

Example: Squaring the result of  78

6=13

[AC] [7] [8] [

] [6] [=]

(continuing) [x

2

]

[=]

Replay Function
This  function  stores  formulas  that  have  been  executed.  
After execution is complete, pressing either the [

] or  [

] key will display the formula executed.
Pressing [

] will display the formula from the beginning, 

with the cursor located under the first character.
Pressing  [

]  will  display  the  formula  from  the  end,  with 

the  cursor  located  at  the  space  following  the  last 
character.  After this, using the [

] and [

] to move the 

cursor, the formula can be checked and numeric values or 
commands can be changed for subsequent execution.

Example: 
[AC] [1] [2] [3] [

] [4] [5] [6] [=]

[

]

[=]

[

]

Example: 
4.12

3.58

6.4 = 21.496

4.12

3.58

7.1 = 7.6496

[AC] [4] [•] [1] [2] [

]

[3] [•] [5] [8] [

] [6] [•] [4] [=]

[

]

[

] [

] [

] [

]

[

] [7] [•] [1]

[=]

The  replay  function  is  not  cleared  even  when  [AC]  is 
pressed or when power is turned OFF, so contents can be 
recalled even after [AC] is pressed.
 
Replay  function  is  cleared  when  mode  or  operation  is 
switched.

 
Error Position Display Function
When  an  ERROR  message  appears  during  operation 
execution,  the  error  can  be  cleared  by  pressing  the  [AC] 
key, and the values or formula can be re-entered from the 
beginning.  However, by pressing the [

] or [

key, the 

ERROR message is cancelled and the cursor moves to the 
point where the error was generated.

Example:  14

0

2.3 is input by mistake

[AC] [1] [4] [

] [0] [

]

[2] [.] [3] [=]

[

] (or [

] )

Correct the input by pressing
[

] [SHIFT] [INS] [1]

[=]

Multistatement Function
• The  multistatement  function  (using  colons  to  separate 

formulas  or  statements)  available  in  program 
calculations can also be used for manual calculations.

•  The  multistatement  function  allows  formulas  to  be 

separated by colons ( [SHIFT] [:] ) to make consecutive, 
multiple statement calculations possible.

• When [=] is pressed to execute a formula input using the 

multistatement  format,  the  formula  is  executed  in  order 

from the beginning.

•  Inputting  "      "  (  [SHIFT]  [      ]  )  in  place  of  the  colon  will 

display  the  calculation  result  up  to  that  point  during 
execution.

Example: 
6.9

123 = 848.7

123

3.2 = 38.4375

[AC]123 [STO] [A] 6.9 [

]

[ALPHA] [A] [SHIFT] [     ]
[ALPHA] [A] [

] 3.2 [=]  

                                  
"Disp" appears on the display when "     " is used.
[=]  

• Even if "    " is not input at the end of a formula, the final 

result will be displayed.

•  Consecutive  calculations  containing  multistatements 

cannot be performed.

        123 

 456 : 

5

                 

 invalid

•  Calculations  can  be  performed  while  an  intermediate 

result is displayed during execution interrupted by "      ".

Example:  5

6     7

8

[AC] [5] [

] [6] [SHIFT] [      ]

[7] [

] [8]

[=]
  

[sin] [Ans]

[=]

When  interrupt  operation  is  completed,  press  [=]  once 
again to execute.
[=]

Scientific Function
Trigonometric  functions  and  inverse  trigonometric 
functions
•  Be  sure  to  set  the  unit  of  angular  measurement  before 

performing trigonometric  function and inverse 

trigonometric function calculations.
•  The  unit  of  angular  measurement  (degrees,  radians, 

grads) is selected in sub-menu.

• Once a unit of angular measurement is set, it remains in 

effect  until  a  new  unit  is  set.    Settings  are  not  cleared 
when power is switched OFF.

• This operation is invalid in the "BASE-N" mode.  When in 
the "BASE-N" mode, go back to COMP mode by selecting 
"COMP" in the main menu.

Logarithmic and Exponential Functions
The  following  operation  is  invalid  in  the  BASE-N  mode.  
When  in  the  BASE-N  mode,  carry  out  calculation  after 
selecting "COMP" mode in main menu.

STO  RCL  CMPLX  SD  LR 

FIX  SCI  ENG

S H A

D R G

PAUSE

ii

0

1

2

3

EXP

Ans

DEL

AC

=

+

4

5

6

7

8

9

+

÷

STO

RCL

(

)

,

;

M+

º

,,,

hyp

sin

cos

tan

tan

–1

M–

Abs

arg

Re

Im

DT CL

cos

–1

ln

log

a

b

/c

d/c

3

x

10

x

e

x

ENG

x

2

x

y

x

3

x

–1

SOLVE

CALC

IN

OUT

LOGIC

DEC

HEX

BIN

OCT

x

!

i

(–)

:

=

SHIFT

ON

ALPHA

MODE

Rnd

Ran#

%

DRG

π

x

A

B

C

r

X

Y

M

Scl

INS

OFF

Mcl

x

n

x

n

–1

x

y

y

y

n

y

n

–1

F

E

sin

–1

D

C

B

A

Pol(

nPr

nCr

Rec(

[d]

[h]

[b]

[o]

∫dx

– 1 –

– 2 –

– 3 –

– 4 –

– 8 –

– 12 –

– 16 –

– 20 –

– 9 –

– 13 –

– 17 –

– 21 –

– 10 –

– 14 –

– 18 –

– 22 –

– 11 –

– 15 –

– 19 –

– 23 –

– 5 –

– 6 –

– 7 –

COMP  CMPLX

COMP  CMPLX

SD  REG BASE

DEG  RAD GRA

FIX  SCI NORM

3

E

5

÷

7

42857.14286

D

123_

0.

D

A=

123.

D

_

0.

D

A=

123.

D

123X456

0.

D

B=

56088.

D

_

0.

D

B=

56088.

D

3

E

5

÷

7–42857

0.14285714

D

122_

D

0.

369xx2_

D

0.

2.36

2

_

D

0.

122

D

0.

123_

D

0.

cos 60

D

0.

sin 60

D

0.

cos 60

D

0.

369x2

D

0.

2.36

2

D

0.

 .36

2

D

0.

sin .36

2

D

0.

 

 

Display

Example 

Operation 

(Lower)

23 + 4.5 –53 =–25.5
56

(–12)

(–2.5)=268.8

12369

7532

74103= 

6.903680613

10

12

(4.5

10

75

)

(–2.3

10

–79

) =  –1.035

10

–3

(2+3)

10

2

=500

(1

10

5

)

7=

14285.71429
(1

10

5

)

7

14285=

0.7142857 
please note that internal calculation is calculated
in 12 digits for a mantissa and the result is
displayed and rounded off to 10 digits. 
 3 + 5 

 

6 = 33

 7 

 8 

 4 

 5 = 36

 1 

 2 

 3 

 4 

 5 

 6

= 6.6
100 

 (2

3) 

 4 = 80

 3 

 ( 4 

 5 ) = 29

( 7 

 2 ) 

 ( 8 

 5 ) = 65

10 

 { 2 

 7 

 ( 3 

 6 )}

= –55

23 [

] 4.5 [

] 53 [=]

56[

][(–)]12[

][(–)]2.5[=]

12369[

] 7532 [

]

74103[=]
4.5[EXP]75 [

] [(–)]2.3

[EXP] [(–)]79 [=]
[( ] 2 [

] 3[ )][

] 1

[EXP]2 [=]
1[EXP]5 [

] 7 [=]

1[EXP]5[

]7 [

]

14285 [=]
 
 
 
3 [

] 5 [

] 6 [=]

7 [

] 8 [

] 4 [

] 5 [=]

1 [

] 2 [

] 3 [

] 4 [

]

5 [

] 6 [=]

100 [

][( ] 2 [

] 3[ )]

[

] 4 [=]

2 [

] 3 [

] [(] 4 [

] 5 [=]

Closed parentheses
occurring immediately
before operation of the
[=] key may be omitted.
[( ] 7 [

] 2 [ )][( ] 8 [

] 5 [=]

A multiplication sign [

]

occurring immediately
before an open parantheses
can be omitted.
10 [

][( ] 2 [

] 7 [( ] 3 [

]

6 [=]

–25.5
268.8

            6.903680613

12

            

            –1.035

–03

            

500.

      14285.71429

0.71428571

 
 
 

33.
36.

6.6

80.
29.

65.

–55.

 

 

Display

Example 

Operation 

(Lower)

sin 63º52'41"
= 0.897859012

cos (

π

/3 rad) = 0.5

tan (–35 grad)
= –0.612800788

2sin45º

cos65º

= 0.597672477
sin

–1

 0.5 = 30

cos

–1

 (

2/2)

= 0.785398163 rad

π

/4 rad

tan

–1

 0.741

= 36.53844577º
= 36º32' 18.4"
If the total number of digits for degrees/minutes/seconds exceed
11 digits, the higher order values are given display priority, and
any lower-order values are not displayed.  However, the entire
value is stored within the unit as a decimal value.
2.5

(sin

–1

0.8

cos

–1

0.9)

= 68º13'13.53"

[MODE][MODE][=]

("DEG" selected)

[sin] 63 [º ' "] 52 [º ' "]
41 [º ' "][=]
[MODE][MODE][

][=]

("RAD")

[cos][(] [SHIFT][

π

][

]3 

[)] [=]
[MODE][MODE][

][

][=]

("GRA" selected)

[tan] [(–)] 35 [=]
[MODE][MODE][=]

("DEG")

2[sin] 45 [cos] 65 [=]
[SHIFT][sin

–1

] 0.5 [=]

[MODE][MODE][

][=]

("RAD")

[SHIFT][cos

–1

][(][

]2 [

]2

[)][=]
[

][SHIFT][

π

][=]

[MODE][MODE][=]

("DEG")

[SHIFT][tan

–1

]0.741[=]

[SHIFT] [

º' "]

 
2.5[

] [(] [SHIFT] [sin

–1

]0.8

[

] [SHIFT] [cos

–1

] 0.9 [)]

[=] [SHIFT] [

º' "]

0.897859012

0.5

–0.612800788

      0.597672477

30.

 
 

0.785398163
0.249999999

36.53844577

36º32º18.4

68º13º13.53

 

 

Display

Example 

Operation 

(Lower)

Percentage
26% of $15.00
Premium
15% increase from
$36.20
Discount
4% discount from
$47.50
Ratio
75 is what % of 250?
Rate of change
141 is an increase of
what % from 120?
Rate of change
240 is a decrease of
what % from 300?

15 [

]26 [SHIFT] [%]

36.2[

]15 [SHIFT] [%] [

]

47.5[

]4 [SHIFT] [%] [

]

75[

]250 [SHIFT] [%]

141[

]120 [SHIFT] [%]

 
240[

]300 [SHIFT] [%]

3.9

            
            

41.63

 

45.6

30.

 

  

17.5

–20.

Norm 1~2?

Fix 0~9?

Sci 0~9?

 

 

Display

Example 

Operation 

(Lower)

100

6 = 16.66666666

specify 4 decimal places
cancel specification

200

7

14 = 400

rounded to 3 decimal
places

100 [

] 6 [=]

[Mode][Mode][Mode][=][4]
[Mode][Mode][Mode]
[

][

][=][1]

200[

]7 [

] 14[=]

[Mode][Mode][Mode][=][3]

200 [

] 7[ =]

The intermediate result is
automatically  rounded
to the specified three
decimal  places.

16.66666667

16.6667

            

16.66666667

            400.

            400.000

28.571

 

 

Display

Example 

Operation 

(Lower)

The stored 10-digit
result (28.571421857) is
used when you continue
the calculation by simply
pressing [

] or any other

arithmetic function key.

Cancel specification by
specifying Norm 1 again.

[

]

14 [=]
(The final result is
automatically  rounded to
the specified three
decimal  places.)
[Mode][Mode][Mode]
[

][

][=][1]

Ans 

            

(upper display)

400.000

400.

 

 

Display

Example 

Operation 

(Lower)

200

7

14 = 400

rounded to 3 decimal
places

round the stored 
intermediate result to
the specified three 
decimal places

Cancel specification by
specifying Norm1 again.

200[

]7 [

] 14[=]

[Mode][Mode][Mode][=][3]

200[

]7 [=]

The intermediate result is
automatically  rounded
to the specified three
decimal  places.
[SHIFT] [RND]

[

]

14 [=]
[Mode][Mode][Mode]
[

][

][=][1]

400.

400.000

28.571

28.571

Ans 

            

(upper display)

399.994
399.994

 

 

Display

Example 

Operation 

(Lower)

100

6 = 16.66666666

specify 5 significant
digits
Cancel specification by
specifying Norm 1 again.

100[

]6 [=]

[Mode][Mode][Mode][

]

[=][5]
[Mode][Mode][Mode]
[

][

][=][1]

16.66666667

1.6667

01

16.66666667

 

 

Display

Example 

Operation 

(Lower)

123m

456 = 56088m

 

= 56.088km

78g

0.96  = 74.88g

 

= 0.07488kg

123[

]456 [=]

[ENG]
78[

]0.96 [=]

[SHIFT] [ENG]

56088.

56.088

03

74.88

0.07488

03

AXB_

0.

D

78

÷

6

13.

D

Ans

2

_

13.

D

Ans

2

169.

D

123x456

56088.

D

123x456

56088.

D

123x456_

56088.

D

C=

6898824.

D

_

0.

D

C=

6898824.

D

A=log2_

0.

D

A=log2

0.301029995.

D

_

0.

D

A=

0.301029995.

D

123_

0.

D

123

123.

D

_

0.

D

_

0.

D

M=

123.

D

M=

136.

D

M=

123.

D

M=

456.

D

_

0.

D

M=

456.

D

M=

123.

D

456

456.

D

_

0.

D

M=

579.

D

123+456

579.

D

789–Ans_

579.

D

789–Ans

210.

D

3x4

12.

D

Ans

÷

3.14_

12.

D

Ans

÷

3.14

3.821656051

D

1

÷

3x3

1.

D

1

÷

3

0.333333333

D

Ansx3

1.

D

12

12.

D

123x456

56088.

D

4.12x3.58+6.

21.1496

D

4.12x3.58–7.

7.6496

D

14

÷

0x2.3

0.

D

Ma ERROR

12x3.58+6.4_

21.1496

D

12x3.58–7.1_

21.1496

D

14

÷

10x2.3

0.

D

14

÷

10x2.3

3.22

D

6.9xA

848.7

PAUSE

A

÷

3.2

38.4375

5x6  7x8_

0.

D

5x6

30.

PAUSE

D

sin Ans_

30.

PAUSE

D

sin Ans_

0.5

PAUSE

D

7x8

56.

D

4.12x3.58+6.

21.1496

D

Reviews: