Asycube 50 & 80
Operating Manual
©
Copyright Asyril S.A.
000.100.501
Version: A1
Operating Manual - Asycube 50 & 80
35/45
Exchange of the backlight
DANGER !
Be sure that all power sources and other cables to the unit are disconnected before
changing the backlight.
Step 1
Remove the platform module
(A)
Refer to “4.2.2 Remove the
information on how to remove the
platform.
Step 2
Remove the four screws
(B)
Step 3
Remove the backlight
(C)
Step 4
Place the new backlight
Step 5
Screw the four screws (0.2 Nm)
Step 6
Remount the platform module
Figure 4-2 : exchange of the backlight
Configure the Asycube with a new backlight color
You can set the information of the color of the backlight in the Asycube. It is useful for
example to be able to adapt interfaces depending of the color or depending if there is no
backlight.
•
With HMI
To modify the parameter, use the following procedure:
Figure 4-3 : change backlight color in HMI
(A)
(C)
(B)
(A)
(B)
(C)