5-16
Chapter 5: RAID configuration
5.2.4
Rebuilding failed drives
You can manually rebuild failed hard disk drives using the
Rebuild
command in the
Management Menu
.
To rebuild a failed hard disk drive
1.
From the
Management Menu
, select
Rebuild
, and then press <Enter>.
2.
The
PHYSICAL DRIVES SELECTION MENU
displays the available drives connected
to the SATA ports. Select the drive you want to rebuild, and then press <Space>.
Use Cursor Keys to Navigate Between Items And Press Enter To Select An Option
LSI Software RAID Configuration Utility Ver C.05 Sep 17,2010
BIOS Version A.10.09231523R
Rebuild VD(s)
Configure
Initialize
Objects
Rebuild
Check Consistency
Management Menu
SPACE-(De)Select,F10-Start Rebuild,F2-Drive Information,F3-View Virtual Drives
LSI Software RAID Configuration Utility Ver C.05 Sep 17,2010
BIOS Version A.10.09231523R
Port # 1 DISK 77247MB HDS72808PLA380 PF20A60A
Configure
Initialize
Objects
Rebuild
Check Consistency
Management Menu
REBUILD - PHYSICAL DRIVES SELECTION MENU
ONLIN A00-00
FAIL A00-01
0
1
PORT #