Chapter 3: BIOS setup
Chapter 3
CPU_FAN Fan Min. Duty Cycle(%) [20]
Fan Min. Duty Cycle(%) [20]
Use the <+> and <-> keys to adjust the minimum CPU fan duty cycle. The
values range from 0% to 100%. When the CPU temperature is under 40ºC, the
CPU fan will operate at the minimum duty cycle.
CHA_FAN1/2/3/4 Q-Fan Control [Enabled]
[Disabled]
Disables the Chassis Q-Fan control feature.
[Enabled]
Enables the Chassis Q-Fan control feature.
CHA_FAN1/2/3/4 Fan Speed Low Limit [600 RPM]
1/2/3/4 Fan Speed Low Limit [600 RPM]
This item appears only when you enable the
CHA_FAN1/2/3/4 Q-Fan Control
feature and
allows you to disable or set the CHA_FAN1/2/3/4 fan warning speed. Configuration options:
[Ignore] [200 RPM] [300 RPM] [400 RPM] [500 RPM] [600 RPM]
CHA_FAN1/2/3/4 Fan Profile [Standard]
This item appears only when you enable the
CHA_FAN1/2/3/4 Q-Fan Control
feature
and allows you to set the appropriate performance level of the CHA_FAN1/2/3/4 fan.
[Standard] Sets to [Standard] to make the chassis fan automatically adjust depending
on the chassis temperature.
�Silent��
Sets to �Silent�� to minimize the fan speed for quiet chassis fan operation.
[Turbo]
Sets to [Turbo] to achieve maximum chassis fan speed.
[Manual] Sets to [Manual] to assign detailed fan speed control parameters.
The following four items appear only when you set
CHA_FAN1/2/3/4 Fan Profile
to
[Manual].
CHA_FAN1/2/3/4 Upper Temperature [70]
Use the <+> and <-> keys to adjust the upper limit of the chassis temperature.
The values range from 40ºC to 90ºC.
CHA_FAN1/2/3/4 Fan Max. Duty Cycle(%) [100]
Use the <+> and <-> keys to adjust the maximum chassis fan duty cycle. The
values range from 60% to 100%. When the chassis temperature reaches the
upper limit, the chassis fan will operate at the maximum duty cycle.
CHA_FAN1/2/3/4 Lower Temperature [40]
Displays the lower limit of the chassis temperature.
CHA_FAN1/2/3/4 Fan Min. Duty Cycle(%) [60]
Use the <+> and <-> keys to adjust the minimum chassis fan duty cycle. The
values range from 60% to 100%. When the chassis temperature is under 40ºC,
the chassis fan will operate at the minimum duty cycle.
Anti Surge Support [Enabled]
This item allows you to enable or disable the Anti Surge function.
Configuration options: �Disabled�� �Enabled��
Summary of Contents for F2A85-V PRO
Page 1: ...Motherboard F2A85 V PRO ...
Page 20: ...1 8 Chapter 1 Product Introduction Chapter 1 ...
Page 51: ...ASUS F2A85 V PRO 2 31 Chapter 2 To uninstall the APU heatsink and fan assembly 5 3 1 4 2 ...
Page 55: ...ASUS F2A85 V PRO 2 35 Chapter 2 2 3 6 ATX Power connection 1 2 OR OR ...
Page 56: ...2 36 Chapter 2 Hardware information Chapter 2 2 3 7 SATA device connection OR 1 OR 2 ...
Page 64: ...2 44 Chapter 2 Hardware information Chapter 2 ...
Page 104: ...3 40 Chapter 3 BIOS setup Chapter 3 ...
Page 156: ...4 52 Chapter 4 Software support Chapter 4 ...
Page 168: ...5 12 Chapter 5 Multiple GPU technology support Chapter 5 ...