Chapter 5: BIOS Setup
5.4.5
Serial Port Console Redirection
Console Redirection Settings
This item becomes configurable only when you enable the
Console Redirection
item. The
settings specify how the host computer and the remote computer (which the user is using)
will exchange data. Both computers should have the same or compatible settings.
Terminal Type [VT-UTF8]
Allows you to set the terminal type.
[VT100]
ASCII char set.
[VT100+]
Extends VT100 to support color, function keys, et.
[VT-UTF8]
Uses UTF8 encoding to map Unicode chars onto 1 or more bytes
[ANSI]
Extended ASCII char set
Bits per second [57600]
Selects serial port transmission speed. The speed must be matched on the other side.
Long or noisy lines may require lower speeds.
Configuration options: [9600] [19200] [38400] [57600] [115200]
Data Bits [8]
Specify the number of data bits to transmit over the serial interface.
Configuration options: [7] [8]
The following item appears only when you set
Console Redirection
to [Enabled].
COM1/COM2
Console Redirection [Disabled]
Allows you to enable or disable the console redirection feature.
Configuration options: [Disabled] [Enabled]