5-18
Chapter 5: RAID configuration
5.2.5
Checking the drives for data consistency
You can check and verify the accuracy of data redundancy in the selected virtual drive. The
utility can automatically detect and/or detect and correct any differences in data redundancy
depending on the selected option in the
Objects > Adapter
menu.
The
Check Consistency
command is available only for virtual drives included in a RAID 1
or RAID 10 set.
Using the Check Consistency Command
To check data consistency using the
Check Consistency
command
1.
From the
Management Menu
, select
Check Consistency
, and then press <Enter>.
2.
The screen displays the available RAID set(s) and prompts you to select the virtual
drive to check. Press <Space> to select the virtual drive from the
Virtual Drive
sub-
menu, and then press <F10>.
Management Menu
Configure
Initialize
Objects
Rebuild
Check Consistency
CC Of VD(s)
LSI Software RAID Configuration Utility Ver C.05 Apr 5, 2012
BIOS Version A.10.09231523R
Use Cursor Keys To Navigate Between Items And Press Enter To Select An Option
Management Menu
Configure
Initialize
Objects
Rebuild
Check Consistency
Select VD
Virtual Drive(s) Configured
LD RAID Size #Stripes StripSz Status
0 1 148.580GB 2 64 KB ONLINE
Virtual Drives
Virtual Drive 0
LSI Software RAID Configuration Utility Ver C.05 Apr 5, 2012
BIOS Version A.10.09231523R
SPACE-(De)Select, F10-Check Consistency
Summary of Contents for ESC2000
Page 1: ...Workstation ESC2000 G2 User Guide ...
Page 27: ...2 7 ASUS ESC2000 G2 B A 9 B A 7 8 5 6 ...
Page 48: ...Chapter 2 Hardware setup 2 28 ...
Page 65: ...ASUS ESC2000 G2 3 17 Connect to 5 1 channel Speakers Connect to 7 1 channel Speakers ...
Page 174: ...5 44 Chapter 5 RAID configuration ...
Page 202: ...6 28 Chapter 6 Driver installation 9 Click Finish to complete the installation ...
Page 205: ...ASUS ESC2000 G2 6 31 6 Click Finish to complete the installation and exit the wizard ...