Batteries maintain power to the controller cache in the event of a power failure, thus protecting any data that
has not been written to a physical drive.
To view battery information:
1. Click the
Device
tab.
2. Click the
Component List
icon.
3.
Click the battery you want, then click the
View
button.
Battery information includes:
• Battery ID
• Operational status – Fully charged, recondition means a reconditioning is in process
• Battery chemistry – LiON, etc.
• Remaining capacity – Battery capacity as a percentage
• Battery cell type – Number of cells
• Estimated hold time – Time in hours that the battery can power the cache
• Temperature threshold discharge – Maximum temperature allowed when the battery is discharging
• Temperature threshold charge – Maximum temperature allowed when the battery is charging
• Battery temperature – Actual battery temperature
• Cycle count – Number of times the battery was reconditioned
• Voltage in millivolts
• Current in milliamps
r
econDItIonInG
a
b
attery
Batteries maintain power to the controller cache in the event of a power failure, thus protecting any data that
has not been written to a physical drive. Reconditioning is the action of discharging and recharging a battery to
preserve its capacity and performance.
Reconditioning is a background activity, it might affect I/O performance. When the recondition is completed,
the battery’s cycle count increments by one.
Battery reconditioning is disabled by default. You can change the reconditioning status and schedule.
To recondition a battery immediately:
1. Click the
Device
tab.
2. Click the
Component List
icon.
3.
Click the battery you want, then click the
Recondition
button.
Battery operations status changes to “Recondition” and the battery’s remaining capacity and estimated hold
time fall and rise reflecting the discharge and recharge cycles of the reconditioning. That behavior is normal.
M
Aking
s
chedule
c
hAnges
To make changes the scheduled battery reconditioning:
1. Click the
Administration
tab.
2. Click the
Background Activities
icon.
The list of Background Activities displays.
3. Click the
Scheduler
button.
4. Mouse-over
Battery Reconditioning
and click the Settings button.
5. Make settings changes as required:
• Start Time
• Uncheck the Enable This Schedule box to disable this activity.
• Recurrence Pattern
• Start From
• End On
6. Click the
Save
button to apply the new settings.