Predictive Data Migration (PDM) migrates data from the suspect physical drive to a spare drive
before
the
physical drive fails.
Before you can run PDM, you must have a replacement or target physical drive of adequate capacity for your
disk array.
To run PDM on a disk array:
1. From the Main Menu, highlight
Disk Array Management
and press
Enter
.
2. Highlight the disk array you want and press
Enter
.
3. Highlight
Background Activities
and press
Enter
.
4. Highlight
Predictive Data Migration
and press
Enter
.
Default source and target drives are shown with possible alternative choices.
5. To choose different drive, highlight the drive, press the backspace key to remove the current number, then
type a new number.
6. Highlight
Start
and press
Enter
.
See "Enabling Media Patrol, PDM, and Power Management on a Disk Array (CLU)" on page 135.
For PDM rate, see "Making Background Activity Settings (CLU)" on page 154.
r
unnInG
t
ranSItIon
on
a
D
ISk
a
rray
(clu)
Transition is the process of replacing a revertible spare drive that is currently part of a disk array with an
unconfigured physical drive or a non-revertible spare drive. For more information, see “Transition” on page 193.
In order to run Transition:
•
The spare drive must be Revertible.
• You must have an unconfigured physical drive of the same or larger capacity to replace the spare drive.
To run Transition on a disk array:
1. From the Main Menu, highlight
Disk Array Management
and press
Enter
.
2. Highlight the disk array you want and press
Enter
.
3. Highlight
Background Activities
and press
Enter
.
4. Highlight
Transition
and press
Enter
.
Default source and target drives are shown with possible alternative choices.
5. To choose different drive, highlight the drive, press the backspace key to remove the current number, then
type a new number.
6. Highlight
Start
and press
Enter
.
For transition rate, see "Making Background Activity Settings (CLU)" on page 154.
l
ocatInG
a
D
ISk
a
rray
(clu)
This feature helps you identify the physical drives assigned to the disk array you are working with in the CLU.
To locate a disk array:
1. From the Main Menu, highlight
Disk Array Management
and press
Enter
.
2. Highlight the disk array you want and press
Enter
.
3. Highlight
Locate Disk Array
and press
Enter
.
The drive carrier status LEDs flash for one minute.