VFACE BASIC and VFACE TOUCH are basicly same hardware instead touch screen. All the functions and 
programming interfaces are same. 

CONNECTION 

 

 

Power Supply : 

12VDC

 

Ethernet Port : 

Standart ethernet connection port.

 

INPUTS : 

2 Digital Inputs. Need to contact with comman (C) port to trigger.

 

 

Input 1 (I1) 

 Closes all in door units, for emergency situation. 

 

Input 2 (I2) 

 

Search indoor units. 

Port 1 : 

Can be used only for VRF connection.

 

Port 2 : 

Can be used for BMS (Modbus/KNX) or VRF connection.

 

You need to mention which brand of VRF and BMS port will be placed on VFACE when you order. 

Summary of Contents for VFACE basic

Page 1: ...Ethernet Port Standart ethernet connection port INPUTS 2 Digital Inputs Need to contact with comman C port to trigger Input 1 I1 Closes all in door units for emergency situation Input 2 I2 Search ind...

Page 2: ...ering up device Default IP address 192 168 2 100 Default Web port 8080 All setup and parameters are being made via browser Enter 192 168 2 100 8080 to your browser prefer Chrome or Firefox browsers lo...

Page 3: ......

Page 4: ...BMS port only for Modbus communication Modbus TCP Port Modbus TCP port setting default value is 1502 CH1 Indoor ID Modbus device ID to access Indoor Units CH1 Outdoor ID Modbus device ID to access Ou...

Page 5: ...y License Key If you want to use extra features of VFace such as Outdoor Unit information KNX communication or VCloud you need to send us Serial Number and Activation Key And we ll produce a new Licen...

Page 6: ...Choose the section you want to delete from combo box and press button Assigned section names automatically will be changed if it s deleted You need to recheck Edit Section Choose the section you want...

Page 7: ...System will always apply the set temperature and mod of rule regardless of time option Remove Press Remove button to delete rule For each rule only a section or a unit can be defined but you can add m...

Page 8: ...o indoor units which you want to control simultaneously There is no feedback information for broadcast you can get feedback from every indoor unit seperetaly KNX is an optional feature you need to ord...

Page 9: ...exadecimal number system same as in VFace search results Tool will Show modbus addresses automatically Modbus point and register types are shown in the table you may check value cells to understand ho...

Page 10: ...emoving this error these sign will dissapear automatically Every VRF brand has its own error code list you must take it as a reference MOBILE INTERFACE Mobile interface has limited functions it only a...

Page 11: ......

Reviews: